TS Messages

TS-1001

Message: NTP query to configured external clock servers(s) failed. Local clock time will be used.

Message Type: LOG

Severity: WARNING

Probable Cause: Indicates a network time protocol (NTP) query to the configured external clock server failed. When next server is not configured local clock time is used for synchronization. This might be logged during temporary operational issues such as IP network connection issues to the external clock server. If it does not recur, it can be ignored.

Recommended Action: Verify the configured external clock server is available and functional. If that external clock server is not available, choose another.

TS-1002

Message: <Type of clock server used> Clock Server used instead of <Type of clock server configured>: locl: 0x<Reference ID of LOCL> remote: 0x<Reference ID of external clock server>.

Message Type: LOG

Severity: INFO

Probable Cause: Indicates that the switch time synchronization was sourced from an alternate clock server instead of the configured clock server. The clock server used can be one of the following type:

• LOCL - Local switch clock.

• External - External Network Time Protocol (NTP) server address configured.

This message may be logged during temporary operational issues such as IP network connection issues to the external clock server. If the message does not recur, it can be ignored.

Recommended Action: Execute the show ntp status command to verify that the switch clock server IP address is configured correctly.

Verify if this clock server is accessible to the switch and functional. If it is not accessible or functional, configure an accessible and functional clock server or reset the clock server to local clock server (LOCL).

TS-1008

Message: <New clock server used> Clock Server used instead of <Old server configured>. System time changed from <Old time> to <New time>.

Message Type: LOG

Severity: INFO

Probable Cause: Indicates that the source of switch time synchronization was changed to another configured clock server because the Network Time Protocol (NTP) query to the current active external clock server failed.

Recommended Action: No action is required. New clock server synchronization will adjust the clock time.

TS-1009

Message:Event: change time: attempt.

Message Type: AUDIT

Class: SECURITY

Severity: INFO

Probable Cause: Indicates an attempt to change the switch time.

Recommended Action: No action is required.

TS-1010

Message: Event: change time: <success or fail>, Info: <result detail>.

Message Type: AUDIT

Class: SECURITY

Severity: INFO

Probable Cause: Indicates the status of the switch time change.

Recommended Action: No action is required.

TS-1011

Message: Event: change time zone: attempt.

Message Type: AUDIT

Class: SECURITY

Severity: INFO

Probable Cause: Indicates an attempt to change the time zone.

Recommended Action: No action is required.

TS-1012

Message: Event: change time zone: <success or fail>, Info: <result detail>.

Message Type: AUDIT

Class: SECURITY

Severity: INFO

Probable Cause: Indicates the status of the time zone change.

Recommended Action: No action is required.

TS-1013

Message: Event: Clock Server change, Status: success, Info: <New clock server used> Clock Server used instead of <Old server configured>. System time changed from <Old time> to <New time>.

Message Type: AUDIT

Class: SECURITY

Severity: INFO

Probable Cause: Indicates that the clock server and the system time have been changed.

Recommended Action: No action is required.