You can display the system message log by using the show logging raslog command. This command provides options to filter the messages by attribute, message type, severity, or message count. You can also specify that messages be displayed for a single module by using the blade option. Use the clear logging raslog command to delete the system messages.
To display the saved RASLog messages, perform the following steps.
device# show logging raslog SLX-OS: v17r.2.00 2017/06/04-22:57:00, [HASM-1108], 94,, INFO, SLX9850-8, All service instances become active. 2017/06/04-22:57:03, [DCM-1002], 96,, INFO, SLX9850-8, PostBoot processing on global config has started. 2017/06/04-22:57:05, [BL-1000], 100,, INFO, SLX9850-8, Initializing ports... 2012/06/13-05:10:22, [NSM-1004], 4428, DCE, INFO, sw0, Interface Vlan 1 is created. 2017/06/13-05:10:24, [DOT1-1013], 4435, DCE, INFO, sw0, DOT1X test timeout value is set to 10. 2017/06/13-05:10:24, [ONMD-1002], 4437, DCE, INFO, sw0, LLDP global configuration is changed. 2017/06/13-05:10:28, [RAS-2001], 4438,, INFO, sw0, Audit message log is enabled. [...]
To display the saved messages for a specific interface module, line card (LC), or management module, perform the following steps.
device# show logging raslog blade LC2 severity info SLX: 17r.2.00 2017/06/22-17:47:46, [HASM-1004], 52, INFO, SLX9850-8, Processor reloaded - Reset. 2017/06/22-17:47:46, [HASM-1104], 53, INFO, SLX9850-8, Heartbeat to M1 up. 2017/06/22-17:47:52, [HSL-1027], 57, L2/0 | Active, INFO, SLX-WESCON-R1, Packet buffers initialized (6G) 2017/06/22-17:51:02, [HASM-1108], 93, L2/0 | Active, INFO, SLX9850-8, All service instances become active. 2017/06/22-17:51:02, [HASM-1134], 94, L2/0 | Active, INFO, SLX9850-8, All service instances on Active. 2017/06/22-18:03:45, [RAS-1001], 184, L2/0 | Active, INFO, SLX9850-8, First failure data capture (FFDC) event occurred. 2017/06/22-18:39:43, [HASM-1004], 298, L2/0 | Standby, INFO, SLX9850-8, Processor reloaded - Reset. 2017/06/22-18:39:43, [HASM-1104], 299, L2/0 | Standby, INFO, SLX9850-8, Heartbeat to M1 up. 2017/06/22-18:39:51, [HSL-1027], 305, L2/0 | Active, INFO, SLX-WESCON-R1, Packet buffers initialized (6G) 2017/06/22-18:43:01, [HASM-1108], 339, L2/0 | Active, INFO, SLX9850-8, All service instances become active. 2017/06/22-18:43:01, [HASM-1134], 340, L2/0 | Active, INFO, SLX9850-8, All service instances on Active. 2017/06/22-18:45:42, [RAS-1001], 407, L2/0 | Active, INFO, SLX9850-8, First failure data capture (FFDC) event occurred. 2017/09/14-23:27:32, [HASM-1004], 648, INFO, SLX9850-8, Processor reloaded - Reset, HW reset reason : Plt Reset. 2017/09/14-23:27:32, [HASM-1104], 649, INFO, SLX9850-8, Heartbeat to M1 up. 2017/09/14-23:27:43, [HSL-1027], 657, L2/0 | Active, INFO, SLX-F8-Hamza-VS, Packet buffers initialized (6G) 2017/09/14-23:30:21, [HASM-1108], 720, L2/0 | Active, INFO, SLX9850-8, All service instances become active. 2017/09/14-23:30:21, [HASM-1134], 721, L2/0 | Active, INFO, SLX9850-8, All service instances on Active. [...]
This section provides information on viewing and clearing the SYSTEM messages saved on the switch memory.
Displaying the SYSTEM messages: To display the messages that are saved in the SYSTEM storage repository, perform the following steps.
device# show logging raslog message-type SYSTEM SLX-OS: v17r.2.00 2017/09/14-04:52:05, [LOG-1003], 1,, INFO, VDX6720-60, SYSTEM error log has been cleared. 2017/09/14-04:56:18, [DCM-1101], 2,, INFO, VDX6720-60, Copy running-config to startup-config operation successful on this node. 2017/09/14-05:05:21, [RAS-1007], 5,, INFO, VDX6720-60, System is about to reboot. [...]
Enter the clear logging raslog message-type SYSTEM command to clear all system messages from the local switch.
This section provides information on viewing and clearing the DCE messages that are saved in the switch memory.
Displaying the DCE messages: To display the saved DCE messages, perform the following steps.
device# show logging raslog message-type DCE SLX: 17r.2.00 2017/09/30-21:25:34, [NSM-1004], 41, M1 | DCE, INFO, switch, Interface Vlan 4093 is created. 2017/09/30-21:25:34, [NSM-1019], 42, M1 | DCE, INFO, switch, Interface Vlan 4093 is administratively up. 2017/09/30-21:25:52, [DOT1-1013], 50, M1 | DCE, INFO, switch, DOT1X test timeout has set to 10. 2017/09/30-21:25:52, [ONMD-1002], 59, M1 | DCE, INFO, switch, LLDP global configuration is changed. 2017/09/30-21:25:53, [SSMD-1602], 63, M1 | DCE, INFO, switch, Class map default is created. 2017/09/30-21:25:55, [NSM-1004], 58, M1 | DCE, INFO, switch, Interface Vlan 1002 is created. 2017/09/30-21:25:55, [ONMD-1002], 59, M1 | DCE, INFO, switch, LLDP global configuration is changed. 2017/09/30-21:25:59, [SSMD-1602], 63, M1 | DCE, INFO, switch, Class map default is created [...]
Clearing the DCE messages: To clear the DCE messages for a particular switch instance, perform the following steps.
Enter the clear logging raslog message-type DCE command to clear all DCE messages from the local switch.
This section provides information on viewing the FFDC messages that are saved in the switch memory.
To display the saved FFDC messages, perform the following steps.
device# show logging raslog attribute FFDC SLX: 17r.2.00 2017/06/22-17:53:07, [HASM-1200], 150, M1 | Active | FFDC, WARNING, SLX9850-8, Detected termination of process mpls_main:5834. 2017/09/14-23:28:18, [HASM-1200], 666, L1/0 | Active | FFDC, WARNING, SLX9850-8, Detected termination of process hslagtd:2915.
To display the description of the RASLog modules, perform the following steps.
device# rasman description RASModule ID Description ------------------------------------------------------- KT 1 Kernel Test ID UT 2 User Test ID TRCE 3 Trace Subsystem (User) KTRC 4 Trace Subsystem (Kernel) LOG 5 RASLOG module CDR 6 Condor ASIC driver [...]
To display the list of all RASLog messages in a module with their message text, perform the following steps.
device# rasman module name AUTH RAS Message ID Severity Message ------------------------------------------------------------------ AUTH-1001 INFO %s has been successfully completed. AUTH-1002 ERROR %s has failed. AUTH-1003 INFO %s type has been successfully set to %s. AUTH-1004 ERROR Failed to set %s type to %s. AUTH-1005 ERROR Authentication file does not exist: %d. AUTH-1006 WARNING Failed to open authentication configuration file. AUTH-1007 ERROR The proposed authentication protocol(s) are not supported: port %d. AUTH-1008 ERROR No security license, operation failed. [...]
Displaying RASLog messages by type: To display the list of RASLog messages that are based on the message type, perform the following steps.
device# rasman type value AUDIT RAS Message ID Severity Message ------------------------------------------------------------------ FCIP-1002 INFO An IPsec/IKE policy was added FCIP-1003 INFO An IPsec/IKE policy was deleted AUTH-1045 ERROR Certificate not present in this switch in %s port %d. AUTH-1046 INFO %s has been successfully completed. AUTH-1047 ERROR %s has failed. AUTH-3001 INFO Event: %s, Status: success, Info: %s type has been changed from [%s] to [%s]. AUTH-3002 INFO Event: %s, Status: success, Info: %s. AUTH-3003 INFO Event: %s, Status: success, Info: %s the PKI objects. [...]