BLL Messages

BLL-1000

Message: ASIC driver detected <slot string> port <port number> as faulty (reason: <reason code>).

Message Type: FFDC | LOG

Severity: CRITICAL

Probable Cause: Indicates that an interface module regulation problem was reported on the specified slot. The interface module is faulted.

The reason codes are as follows:

1 = Available buffer overflow

2 = Backend port buffer timeout

3 = Backend port got shut down

4 = Embedded port buffer timeout

5 = Excessive busy mini buffer

6 = Excessive RCC VC on E_Port

7 = Excessive RCC VC on FL_Port

8 = Fail detection buffer tag error

9 = Fail detection TX parity error

10 = EPI CMEM interrupt error

11 = Checkpoint Middleware Interface (CMI) interrupt error

12 = Interrupt overrun

13 = FDET interrupt

14 = Interrupt suspended

15 = Filter LISTD error

16 = Unknown filter LIST error

17 = Wait for LPC open state

18 = Wait for Old port state

19 = Wait for Open init state

20 = TX parity error

21 = RAM parity error

22 = Built in Self Repair (BISR) or RAMINIT error

Recommended Action:

Make sure the interface module is seated correctly. If the interface module is seated correctly, reload or power cycle the interface module using the power-off and power-on commands.

Execute the diag systemverification command to verify that the interface module does not have hardware problems.

If the message persists, replace the interface module.