Message: HSL initialization failed.
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates a hardware subsystem layer (HSL) initialization failure. This error is caused by other system errors.
Recommended Action: Execute the copy support command and contact your switch service provider.
Message:Failed to acquire the system MAC address pool.
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates the failure to acquire the system address. This error is caused by other system errors.
Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.
Message: Incompatible SFP transceiver for interface <InterfaceName> is detected.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been inserted.
Recommended Action: Disable the interface using the shutdown command and insert an SFP transceiver that is supported on the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown command
Message: Failed to get the kernel page size <PageSize> bytes for the Memory Map (MMap).
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates that there is not enough contiguous kernel memory.
Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.
Message: Failed to create Extreme trunk interface <InterfaceName>.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates failure to create Extreme trunk because the hardware resources are exhausted.
Recommended Action: Do not exceed the maximum trunk configuration allowed by the system.
Message: Reached max VRBIDs usage, VRB-ID allocation failed in ASIC.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that maximum VRBIDs have been used.
Recommended Action: No action is required.
Message: Resource limit reached, <Number of resources to be freed.> resources are required for the virtual-fabric entry.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates that maximum resources have been used.
Recommended Action: No action is required.
Message: interface <InterfaceName> received remote fault.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates interface has received a remote fault from peer.
Recommended Action: No action is required.
Message: interface <InterfaceName> detected local fault.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates interface has detected a local fault.
Recommended Action: No action is required.
Message: Remote fault cleared on interface <InterfaceName>.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates remote fault is cleared on interface.
Recommended Action: No action is required.
Message: Local fault cleared on interface <InterfaceName>.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates local fault is cleared on interface.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not Extreme branded.
Message Type: LOG
Severity: INFO
Probable Cause: Indicates optic is not Extreme branded.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not compatible.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates optic is not compatible with current port configuration.
Recommended Action: No action is required.
Message: FEC Resources on LC: <linecardid> unit: <unit> are exhausted. Time since last log <current_time> and total fail count: <fail_count>.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates FEC resources are exhausted on the unit of line card.
Recommended Action: No action is required.
Message: <msg>
Message Type: LOG
Severity: INFO
Probable Cause: None
Recommended Action: None.
Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].
Message Type: LOG
Severity: INFO
Probable Cause: Indicates status for Offline Diagnostic Test for a line card / SFM.
Recommended Action: No action is required.
Message: Offline Diagnostic Test on file no found on <lc_sfm_type>: <linecardid>.
Message Type: LOG
Severity: WARNING
Probable Cause: Indicates Offline Diagnostic Test file not present on a line card / SFM.
Recommended Action: No action is required.
Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].
Message Type: LOG
Severity: CRITICAL
Probable Cause: Indicates failure status for Offline Diagnostic Test for a line card / SFM.
Recommended Action: No action is required.
Message: Optic inserted in interface <InterfaceName> is not compatible and laser is disabled.
Message Type: LOG
Severity: ERROR
Probable Cause: Indicates optic is not compatible with current port configuration.
Recommended Action: No action is required.
Message: <msg>
Message Type: LOG
Severity: INFO
Probable Cause: None
Recommended Action: None.
Message: Temperature of optic inserted in interface <InterfaceName> is above critical threshold and it is put in reset.
Message Type: LOG
Severity: CRITICAL
Probable Cause:Indicate the optic temperature in the cage is over critical threshold
Recommended Action: Replace a new optic and do shut/no shut on the port.
Message: Temperature of optic inserted in interface <InterfaceName> is above warning threshold.
Message Type: LOG
Severity: WARNING
Probable Cause:Indicate the optic temperature in the cage is over warning threshold
Recommended Action: Replace a new optic and do shut/no shut on the port.