HSL Messages

HSL-1000

Message: HSL initialization failed.

Message Type: LOG

Severity: CRITICAL

Probable Cause: Indicates a hardware subsystem layer (HSL) initialization failure. This error is caused by other system errors.

Recommended Action: Execute the copy support command and contact your switch service provider.

HSL-1001

Message:Failed to acquire the system MAC address pool.

Message Type: LOG

Severity: CRITICAL

Probable Cause: Indicates the failure to acquire the system address. This error is caused by other system errors.

Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.

HSL-1004

Message: Incompatible SFP transceiver for interface <InterfaceName> is detected.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates that an incompatible small form-factor pluggable (SFP) transceiver for the interface has been inserted.

Recommended Action: Disable the interface using the shutdown command and insert an SFP transceiver that is supported on the interface. After the SFP transceiver is inserted, re-enable the interface using the no shutdown command

HSL-1006

Message: Failed to get the kernel page size <PageSize> bytes for the Memory Map (MMap).

Message Type: LOG

Severity: CRITICAL

Probable Cause: Indicates that there is not enough contiguous kernel memory.

Recommended Action: Execute the show logging raslog command to view the error log for other system errors and correct the errors.

HSL-1009

Message: Failed to create Extreme trunk interface <InterfaceName>.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates failure to create Extreme trunk because the hardware resources are exhausted.

Recommended Action: Do not exceed the maximum trunk configuration allowed by the system.

HSL-1010

Message: Reached max VRBIDs usage, VRB-ID allocation failed in ASIC.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates that maximum VRBIDs have been used.

Recommended Action: No action is required.

HSL-1011

Message: Resource limit reached, <Number of resources to be freed.> resources are required for the virtual-fabric entry.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates that maximum resources have been used.

Recommended Action: No action is required.

HSL-1020

Message: interface <InterfaceName> received remote fault.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates interface has received a remote fault from peer.

Recommended Action: No action is required.

HSL-1021

Message: interface <InterfaceName> detected local fault.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates interface has detected a local fault.

Recommended Action: No action is required.

HSL-1022

Message: Remote fault cleared on interface <InterfaceName>.

Message Type: LOG

Severity: INFO

Probable Cause: Indicates remote fault is cleared on interface.

Recommended Action: No action is required.

HSL-1023

Message: Local fault cleared on interface <InterfaceName>.

Message Type: LOG

Severity: INFO

Probable Cause: Indicates local fault is cleared on interface.

Recommended Action: No action is required.

HSL-1024

Message: Optic inserted in interface <InterfaceName> is not Extreme branded.

Message Type: LOG

Severity: INFO

Probable Cause: Indicates optic is not Extreme branded.

Recommended Action: No action is required.

HSL-1025

Message: Optic inserted in interface <InterfaceName> is not compatible.

Message Type: LOG

Severity: WARNING

Probable Cause: Indicates optic is not compatible with current port configuration.

Recommended Action: No action is required.

HSL-1026

Message: FEC Resources on LC: <linecardid> unit: <unit> are exhausted. Time since last log <current_time> and total fail count: <fail_count>.

Message Type: LOG

Severity: WARNING

Probable Cause: Indicates FEC resources are exhausted on the unit of line card.

Recommended Action: No action is required.

HSL-1027

Message: <msg>

Message Type: LOG

Severity: INFO

Probable Cause: None

Recommended Action: None.

HSL-1028

Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].

Message Type: LOG

Severity: INFO

Probable Cause: Indicates status for Offline Diagnostic Test for a line card / SFM.

Recommended Action: No action is required.

HSL-1029

Message: Offline Diagnostic Test on file no found on <lc_sfm_type>: <linecardid>.

Message Type: LOG

Severity: WARNING

Probable Cause: Indicates Offline Diagnostic Test file not present on a line card / SFM.

Recommended Action: No action is required.

HSL-1030

Message: Offline Diagnostic Test on <lc_sfm_type>: <linecardid> status: <log_status> [<result_updated>].

Message Type: LOG

Severity: CRITICAL

Probable Cause: Indicates failure status for Offline Diagnostic Test for a line card / SFM.

Recommended Action: No action is required.

HSL-1031

Message: Optic inserted in interface <InterfaceName> is not compatible and laser is disabled.

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates optic is not compatible with current port configuration.

Recommended Action: No action is required.

HSL-1032

Message: <msg>

Message Type: LOG

Severity: INFO

Probable Cause: None

Recommended Action: None.

HSL-1033

Message: Temperature of optic inserted in interface <InterfaceName> is above critical threshold and it is put in reset.

Message Type: LOG

Severity: CRITICAL

Probable Cause:Indicate the optic temperature in the cage is over critical threshold

Recommended Action: Replace a new optic and do shut/no shut on the port.

HSL-1034

Message: Temperature of optic inserted in interface <InterfaceName> is above warning threshold.

Message Type: LOG

Severity: WARNING

Probable Cause:Indicate the optic temperature in the cage is over warning threshold

Recommended Action: Replace a new optic and do shut/no shut on the port.