QOSD Messages

QOSD-1000

Message: QoS initialized successfully.

Message Type:LOG

Severity:INFO

Probable Cause: Indicates that the Data Center Ethernet (DCE) QoS has been initialized.

Recommended Action: No action is required.

QOSD-1001

Message:Failed to allocate memory: (<function name>).

Message Type: LOG

Severity: ERROR

Probable Cause: Indicates that the specified function has failed to allocate memory.

Recommended Action: Check the memory usage on the switch using the show process memory command.

Restart or power cycle the switch.

QOSD-1005

Message: QoS startup failed.

Message Type:LOG

Severity:ERROR

Probable Cause: Indicates that the Data Center Ethernet (DCE) QoS encountered an unexpected severe error during basic startup and initialization.

Recommended Action: Restart or power cycle the switch.

If the problem persists, download a new firmware version using the firmware download command.

QOSD-1006

Message: Interface <interface_name> is not allowed to come up as ISL because of Long Distance ISL restriction. Shutting down interface.

Message Type:LOG

Severity:ERROR

Probable Cause: Indicates that the interface could not come up as inter-switch link (ISL) because only regular ISL is allowed for 2 Km and 5 Km distant links. The interface has been automatically shut down.

Recommended Action: No action is required.

QOSD-1007

Message: sFlow profile <sflow-profile-name> is not present.

Message Type:DCE

Severity:ERROR

Probable Cause: Indicates that the specified sFlow profile is not configured on the system.

Recommended Action: No action is required.

QOSD-1008

Message: Classmap <class-map_name> is already applied on RBridge in dir <direction> through policy-map <policy-map_name>.

Message Type: DCE

Severity:ERROR

Probable Cause: Indicates that the specified class-map is already applied on the RBridge.

Recommended Action: No action is required.

QOSD-1500

Message: <BUM_protocol_name> traffic rate has been exceeded on interface <interface_name>.

Message Type: DCE

Severity:INFO

Probable Cause: Indicates that the broadcast, unknown unicast, and multicast (BUM) monitor routine has detected a rate violation.

Recommended Action: No action is required.

QOSD-1501

Message: <BUM_protocol_name> traffic rate returned to conforming on interface <interface_name>.

Message Type:DCE

Severity:INFO

Probable Cause:Indicates that broadcast, unknown unicast, and multicast (BUM) storm control has detected that the traffic rate has returned to the normal limit on the specified interface.

Recommended Action: No action is required.

QOSD-1502

Message: <BUM_protocol_name> traffic rate has been exceeded interface <interface_name>. Interface will be shut down.

Message Type:DCE

Severity:INFO

Probable Cause:Indicates that the broadcast, unknown unicast, and multicast (BUM) monitor routine has detected a rate violation.

The interface has been shut down.

Recommended Action: Disable BUM storm control on the interface using the no storm-control ingress command; then re-enable the interface (using the no shutdown command) and BUM storm control (using the storm-control ingress command).

QOSD-1503

Message: The configured CIR/EIR is less than the minimum supported CIR/EIR (<MinSupportedInformationRate> bps) of this platform, the operational CIR/EIR will be 0.

Message Type:DCE

Severity:INFO

Probable Cause:Indicates that the configured CIR/EIR is less than the supported operation range of platform results in complete drop of traffic matching the policer entry.

Recommended Action: No action is required.

QOSD-1600

Message: Tail drops detected on interface <interface_name>.

Message Type: DCE

Severity: INFO

Probable Cause: Indicates that tail drops are detected on the specified interface.

Recommended Action: No action is required.

QOSD-1601

Message: RED drops detected on interface <interface_name>.

Message Type:DCE

Severity:INFO

Probable Cause: Indicates that red drops are detected on the specified interface.

Recommended Action: No action is required.

QOSD-1700

Message: <msg>

Message Type:DCE

Severity:INFO

Probable Cause: None

Recommended Action: None.

QOSD-1800

Message: Failed to inherit cos mutation map from parent lag <Lag_name> to member interface <interface_name>.

Message Type:DCE

Severity:INFO

Probable Cause: Space is not available on chip to create new qos maps.

Recommended Action: No action is required.

QOSD-1801

Message: Failed to inherit cos tc map from parent lag <Lag_name> to member interface <interface_name>.

Message Type:DCE

Severity:INFO

Probable Cause: Space is not available on chip to create new qos maps.

Recommended Action: No action is required.