If traffic is not moving properly, use the following procedure to determine the
            issue.
     
        Procedure
- 
        Enter Privileged EXEC mode:
        
      
- 
                Ensure that all switch nodes in
                    the network operate with the most recent software release to support IP
                    Multicast over Fabric Connect:
                
            
- 
                Ensure that you create and
                    enable SPBM infrastructure globally.
                
                    - 
                        Ensure that SPBM is
                            enabled globally:
                        
                    
- 
                        Ensure that IS-IS is
                            enabled globally:
                        
                    
- 
                        Ensure an SPBM instance
                            exists with at least one Backbone VLAN (B-VID). Also ensure multicast is
                            enabled:
                        
                    
 
- 
                Ensure that you enable the CFM
                    configuration.
                
                    - 
                        Ensure a CFM
                            maintenance-association exists:
                        
                            show cfm
                                    maintenance-association 
 
- 
                        Ensure a CFM
                            maintenance-domain exists:
                        
                            show cfm
                                    maintenance-domain 
 
- 
                        Ensure a
                            maintenance-endpoint exists in the MEP ID column and is enabled in the
                            ADMIN column:
                        
                            show cfm
                                    maintenance-endpoint 
 
 
- 
                Ensure a Customer VLAN (C-VLAN)
                    exists and ensure you add UNI ports to the C-VLAN.
                
                    - 
                        Display C-VLAN
                            information:
                        
                    
- 
                        Display ports for the
                            C-VLAN:
                        
                            show vlan
                                    members port
                                    {slot/port[/sub-port][-slot/port[/sub-port]][,...]} 
 
- 
                        Display NNI and UNI
                            receivers:
                        
                            show isis
                                    spbm ip-multicast-route detail 
 
 
- 
                Ensure that you assign the same
                    I-SID to the C-VLAN on all of the BEBs where you configure the C-VLAN:
                
            
- 
                Ensure that you enable IP
                    Multicast over Fabric Connect globally:
                
            
- 
                Ensure the you enable IGMP
                    Snooping on the C-VLAN on all of the Backbone Edge Bridges (BEBs). Ensure the
                    protocol configured on the VLAN added is snoop-spb in the MODE column, which
                    indicates IGMP is enabled on a VLAN with an associated I-SID (IP Multicast over
                    Fabric Connect for a Layer 2 VSN):
                
            
- 
                Ensure that you enable IGMP
                    Snooping on access Layer 2 switches to prevent flooding of multicast traffic to
                    non-receiver ports:
                
                    show ip igmp
                            snoop-trace show ip igmp
                            interface 
 
- 
                Ensure that the IGMP version
                    used by the multicast hosts and the Layer 2 switches outside the SPBM network is
                    the same as the IGMP version configured on the C-VLAN: