View Statistical Graph of Remote IS-IS Interface Counters
About this task
Perform this procedure to view statistical graph of the remote IS-IS interface counters.
Procedure
- In the navigation pane, expand the folders.
- Select IS-IS Remote.
- Select the Interfaces tab.
- Select an interface.
- Select the Graph button.
Interface Counters Field Descriptions
The following table describes the fields in the Interface Counters tab.
| Name | Description | 
|---|---|
| InitFails | Indicates the number of times initialization of this circuit has failed. This counts events such as PPP NCP failures. | 
| RejAdjs | Indicates the number of times an adjacency has been rejected on this circuit. | 
| IDFieldLenMismatches | Indicates the number of times an Intermediate-System-to-Intermediate-System (IS-IS) control PDU with an ID field length different from that for this system has been received. | 
| MaxAreaAddrMismatches | Indicates the number of times an IS-IS control PDU with a max area address field different from that for this system has been received. | 
| AuthFails | Indicates the number of times an IS-IS control PDU with the correct auth type has failed to pass authentication validation. | 
| LANDesISChanges | Indicates the number of times the Designated IS has changed on this circuit at this level. If the circuit is point to point, this count is zero. | 
| AbsoluteValue | Displays the counter value. | 
| Cumulative | Displays the total value since you opened the Stats tab. | 
| Average/Sec | Displays the average value for each second. | 
| Minimum/Sec | Displays the minimum value for each second. | 
| Maximum/Sec | Displays the maximum value for each second. | 
| Last Val/Sec | Displays the last value for each second. | 