If traffic is not moving properly, use the following procedure to determine the
            issue.
     
        Procedure
- 
                Ensure that all switch nodes in
                    the network operate with the most recent software release to support IP
                    Multicast over Fabric Connect:
                
            
- 
                Ensure that you create and
                    enable SPBM infrastructure globally.
                
                    - 
                        Ensure that SPBM is
                            enabled globally:
                        
                    
- 
                        Ensure that IS-IS is
                            enabled globally:
                        
                    
- 
                        Ensure an SPBM instance
                            exists with at least one Backbone VLAN (B-VID). Also ensure multicast is
                            enabled:
                        
                    
 
- 
                Ensure that you enable the CFM
                    configuration.
                
                    - 
                        Ensure a CFM
                            maintenance-association exists:
                        
                            show cfm
                                    maintenance-association 
 
- 
                        Ensure a CFM
                            maintenance-domain exists:
                        
                            show cfm
                                    maintenance-domain 
 
- 
                        Ensure a
                            maintenance-endpoint exists in the MEP ID column and is enabled in the
                            ADMIN column:
                        
                            show cfm
                                    maintenance-endpoint 
 
 
- 
                Ensure the following on all the
                    Backbone Edge Bridges (BEBs) where the Layer 3 VSN is present.
                
                    - 
                        Ensure that you enable
                            IP multicast globally:
                        
                    
- 
                        Ensure that you create
                            an IPVPN for the VRF:
                        
                            show ip
                                    ipvpn [vrf WORD<1–16>][vrfids WORD<0–512>] 
 
- 
                        Ensure that you assign
                            an I-SID to the VRF:
                        
                            show isis
                                    spbm ip-multicast-route all 
 
- 
                        Ensure that you enable
                            the MVPN:
                        
                    
 
- 
                On the VLANs that need Layer 3
                    VSN IP Multicast over Fabric Connect routing, create an IP interface on the VLAN
                    if one does not exist. The address should be on the same subnet as the IGMP
                    hosts connected to the VLAN. Also, ensure that you enable IP Multicast over
                    Fabric Connect.
            
- 
        Enter VLAN Interface Configuration
          mode:
        
          enable configure
              terminal interface vlan <1–4059> 
 
- 
                Create an IP interface on the
                    VLAN and enable IP Multicast over Fabric Connect:
                
                    ip address <A.B.C.D> ip spb-multicast
                            enable 
 
- 
                Ensure that you enable IGMP
                    Snooping on access Layer 2 switches to prevent flooding of multicast traffic to
                    non-receiver ports:
                
                    show ip igmp
                            snoop-trace show ip igmp
                            interface 
 
- 
                Ensure that the IGMP version
                    used by the multicast hosts and the Layer 2 switches outside the SPBM network is
                    the same as the IGMP version configured on the C-VLAN: