The Summit X450a series includes the following switches:
| Summit X450a-24t switch Summit X450a-24tDC switch Summit X450a-24x switch Summit X450a-24xDC switch | Height: 1.73 inches (4.4 cm) Width: 17.4 inches (44.1 cm) Depth: 15.3 inches (38.9 cm) | 
| Summit X450a-48t switch Summit X450a-48tDC switch | Height: 1.73 inches (4.4 cm) Width: 17.4 inches (44.1 cm) Depth: 17.0 inches (43.2 cm) | 
| Summit X450a-24t switch | 13.8 lb (6.24 kg) | 
| Summit X450a-24tDC switch | 12.3 lb (5.56 kg) | 
| Summit X450a-24x switch | 13.0 lb (5.9 kg) | 
| Summit X450a-24xDC switch | 12.50 lb (5.67 kg) | 
| Summit X450a-48t switch | 15.8 lb (7.14 kg) | 
| Summit X450a-48tDC switch | 15.5 lb (7.03 kg) | 
| Summit X450a-24t switch Summit X450a-24tDC switch Summit X450a-24x switch Summit X450a-24xDC switch Summit X450a-48t switch Summit X450a-48tDC switch | Height: 5.9 inches (15 cm) Width: 22.4 inches (57 cm) Depth: 21.7 inches (55 cm) | 
| Summit X450a-24t switch | 18.7 lb (8.5 kg) | 
| Summit X450a-24tDC switch | 16.8 lb (7.7 kg) | 
| Summit X450a-24x switch | 18.7 lb (8.5 kg) | 
| Summit X450a-24xDC switch | 16.8 lb (7.7 kg) | 
| Summit X450a-48t switch | 20.4 lb (9.3 kg) | 
| Summit X450a-48tDC switch | 17.75 lb (8.0 kg) | 
| Delta Blower | 2900 RPM/11.3 CFM | 
| Sunon Fan | 7200 RPM/8.9 CFM | 
| Operational voltage range | 90 to 264 V | 
| Nominal input ratings | 100 to 240 V | 
| Input current | 1.0 A @ 115 V 0.5 A @ 230 V | 
| Line frequency range | 47 to 63 Hz | 
| Inrush current | 30 A @ 115 V, 60 A @ 230 V | 
| Power supply cord type | AC | 
| Power supply input socket | IEC 320 C14 | 
| Power cord input plug | IEC 320 C13 | 
| Power cord wall plug | Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. | 
| Power supply cord gauge | 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet | 
| Efficiency | 80% with 60% to 100% load | 
| Heat dissipation | 100 W (341.2 BTU/hr) | 
| Power consumption | 100 W (341.2 BTU/hr) | 
| Operational voltage range | –36 to –72 V | 
| Nominal input ratings | –48 V | 
| Nominal input current | 2.0 A @ -36 V 1.0 A @ -72 V | 
| Inrush current | 20 A @ 48 V, 30 A @ 72 V | 
| Power supply cord type | DC | 
| Power supply input socket | TYCO PN 206061-1 | 
| Power cord input plug | TYCO PN 206060-1 | 
| Power cord wall plug | None provided | 
| Power supply cord gauge | 14 AWG (2.0 mm2) | 
| Heat dissipation, Watts, BTU | 75 W, 255.9 BTU/hr | 
| Power consumption, Watts, BTU | 75 W, 255.9 BTU/hr | 
| Operational voltage range | 90 to 264 V | 
| Nominal input ratings | 100 to 240 V | 
| Nominal input current | 1.45 A @ 115 V 0.65 A @ 230 V | 
| Line frequency range | 47 to 63 Hz | 
| Inrush current | 30 A @ 115 V, 60 A @ 230 V | 
| Power supply cord type | AC | 
| Power supply input socket | IEC 320 C14 | 
| Power cord input plug | IEC 320 C13 | 
| Power cord wall plug | Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. | 
| Power supply cord gauge | 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet | 
| Efficiency | 80% with 60% to 100% load | 
| Heat dissipation | 160 W (512 BTU/hr) | 
| Power consumption, Watts, BTU | 160 W (512 BTU/hr) | 
| Operational voltage range | –36 to –72 V | 
| Nominal input voltage | –48 V | 
| Input current | 4.0 A @ –36 VDC (low-line) 2.0 A @ –72 VDC (high-line) | 
| Inrush current | 29 A @ 48 V, 30 A @ 72 V | 
| Input wire harness | Extreme part number 250088 | 
| Power supply cord gauge | 14 AWG (2.0 mm2) | 
| Power cord input plug | TYCO PN 206060-1 | 
| Power supply input socket | TYCO PN 206061-1 | 
| Operational voltage range | 90 to 264 V | 
| Nominal input ratings | 100 to 240 V | 
| Nominal input current | 1.0 A @ 115 V 0.5 A @ 230 V | 
| Line frequency range | 47 to 63 Hz | 
| Inrush current | 30 A @ 115 V, 60 A @ 230 V | 
| Power supply cord type | AC | 
| Power supply input socket | IEC 320 C14 | 
| Power cord input plug | IEC 320 C13 | 
| Power cord wall plug | Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. | 
| Power supply cord gauge | 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet | 
| Efficiency | 80% with 60% to 100% load | 
| Heat dissipation | 80 W (273 BTU/hr) | 
| Power consumption | 80 W (273 BTU/hr) | 
| Operational voltage range | –36 to –72 V | 
| Nominal input ratings | –48 V | 
| Input current | 2.5 A @ -36 V 1.25 A @ -72 V | 
| Inrush current | 40 A peak maximum | 
| Input wire harness | Extreme Networks PN 250088 | 
| Power supply input socket | TYCO PN 206061-1 | 
| Power cord input plug | TYCO PN 206060-1 | 
| Power cord wall plug | None provided | 
| Power supply cord gauge | 14 AWG (2.0 mm2) | 
| Heat dissipation | 98 W (334 BTU/hr) | 
| Power consumption | 98 W (334 BTU/hr) | 
| CPU/Memory | 
|---|
| 400 MHz CPU | 
| 256 MB memory | 
| North American Safety of ITE | UL 60950-1:2003 1st Ed., Listed Device (US) CSA 22.2#60950-1-03 1st Ed.(Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) IEEE 802.3af 6-2003 Environment A for PoE Applications | 
| European Safety of ITE | EN 60950-1:2001+A11 EN 60825-1+A2:2001 (Lasers Safety) TUV-R GS Mark by German Notified Body 73/23/EEC Low Voltage Directive | 
| International Safety of ITE | CB Report & Certificate per IEC 60950-1:2001 Country Deviations AS/NZX 60950-1 (Australia /New Zealand) | 
| North America EMC for ITE | FCC CFR 47 part 15 Class A (USA) ICES-003 Class A (Canada) | 
| European EMC standards | EN 55022:1998 Class A EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EN 61000-3-2,3 (Harmonics & Flicker) ETSI EN 300 386:2001 (EMC Telecommunications) 89/336/EEC EMC Directive | 
| International EMC certifications | CISPR 22:1997 Class A (International Emissions) CISPR 24:1997 Class A (International Immunity) IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C | 
| Country-specific | VCCI Class A (Japan Emissions) AS/NZS 3548 ACA (Australia Emissions) CNS 13438:1997 Class A (BSMI-Taiwan) MIC Mark, EMC Approval (South Korea) | 
| ETSI EN 300 386:2001 (EMC Telecommunications) ETSI EN 300 019 (Environmental for Telecommunications) | 
| IEEE 802.3ab 1000BASE-T | 
| Environmental standards | EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5G | 
| Operating conditions | Temperature range: 0° C to 40° C (32° F to 104° F) Humidity: 10% to 93% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) Shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks Random vibration: 3 to 500 Hz @ 1.5 G rms | 
| Storage & transportation conditions (packaged) | Transportation temperature: -40° C to 70° C (-40° F to 158° F) Storage and transportation humidity: 10% to 95% relative humidity, non-condensing Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged sine vibration: 5 to 62 Hz @ velocity 5 mm/s, 62 to 500 Hz @ 0.2 G Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz 14 drops minimum on sides & corners @ 42 inches (<15 kg box) | 
| Sound power in accordance with
                                EN 300 753 (10-1997) Summit X450a-24t and X450a-48t | Sound power: 62 dBA per ISO 7779 Declared sound power: 6.4 belsA per ISO 7779 & ISO 9296 | 
| Bystander sound pressure in accordance with NEBS GR-63 Issue 2 Summit X450a-24t and X450a-48t | Bystander sound pressure: 54 dBA right side @ 0.6m |