The Summit X450e series includes the following switches:
Summit X450e-24p switch |
Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 15.30 inches (38.7 cm) |
Summit X450e-48p switch |
Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 17 inches (43.2 cm) |
Summit X450e-24t switch |
Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 15.3 inches (38.9 cm) |
Summit X450e-48t switch |
Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 17.0 inches (43.2 cm) |
Summit X450e-24p switch |
14 lb (6.4 kg) |
Summit X450e-48p switch |
16.25 lb (7.4 kg) |
Summit X450e-24t switch |
11.8 lb (5.4 kg) |
Summit X450e-48t switch |
15.75 lb (7.14 kg) |
Summit X450e-24p switch Summit X450e-48p switch |
Height: 5.9 inches (15 cm) Width: 22.4 inches (57 cm) Depth: 21.7 inches (55 cm) |
Summit X450e-24p switch |
18.9 lb (8.6 kg) |
Summit X450e-48p switch |
21 lb (9.6 kg) |
Summit X450e-24t switch |
26.8 lb (12.16 kg) |
Summit X450e-48t switch |
29.9 lb (13.6 kg) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50/60 Hz, 5.25 A |
Input current |
4.25 A @ 115 V (low-line) 2.0 A @ 230 V (high-line) |
Line frequency range |
47 to 63 Hz |
Inrush current |
30 A @ 115 V, 60 A @ 230 V |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
80% with 60% to 100% load |
Heat dissipation with PoE full load |
120 W (410 BTU/hr) |
Power consumption with PoE full load |
488 W (1,665 BTU/hr) |
Heat dissipation without PoE |
54 W (184 BTU/hr) |
Power consumption without PoE |
54 W (184 BTU/hr) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50/60 Hz, 6.0 A |
Nominal input current |
5.25 A @ 115 V (low-line) 2.5 A @ 230 V (high-line) |
Line frequency range |
47 to 63 Hz |
Inrush current |
30 A @ 115 V, 60 A @ 230 V |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
80% with 60% to 100% load |
Heat dissipation with PoE full load |
180 W (614 BTU/hr) |
Power consumption with PoE full load |
507 W (1,730 BTU/hr) |
Heat dissipation without PoE |
73 W (250 BTU/hr) |
Power consumption without PoE |
73 W (250 BTU/hr) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50/60 Hz, 1.0 A |
Nominal input current |
0.52 A @ 100 V (low-line) 0.31 A @ 240 V (high-line) |
Line frequency range |
47 to 63 Hz |
Inrush current |
30 A @ 115 V, 60 A @ 230 V |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Heat dissipation, Watts, BTU |
52 W (178 BTU/hr) |
Power consumption, Watts, BTU |
52 W (178 BTU/hr) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50/60 Hz, 6 A |
Nominal input current |
0.94 A @ 100 V (low-line) 0.43 A @ 240 V (high-line) |
Line frequency range |
47 to 63 Hz |
Inrush current |
30 A @ 115 V, 60 A @ 230 V |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Heat dissipation |
94 W (321 BTU/hr) |
Power consumption |
94 W (321 BTU/hr) |
North American Safety of ITE |
UL 60950-1:2003 1st Ed., Listed Device (US) CSA 22.2#60950-1-03 1st Ed.(Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) IEEE 802.3af 6-2003 Environment A for PoE Applications |
European Safety of ITE |
EN 60950-1:2001+A11 EN 60825-1+A2:2001 (Lasers Safety) TUV-R GS Mark by German Notified Body 73/23/EEC Low Voltage Directive |
International Safety of ITE |
CB Report & Certificate per IEC 60950-1:2001 Country Deviations AS/NZX 60950-1 (Australia /New Zealand) |
North America EMC for ITE |
FCC CFR 47 part 15 Class A (USA) ICES-003 Class A (Canada) |
European EMC standards |
EN 55022:1998 Class A EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EN 61000-3-2,3 (Harmonics & Flicker) ETSI EN 300 386:2001 (EMC Telecommunications) 89/336/EEC EMC Directive |
International EMC certifications |
CISPR 22:1997 Class A (International Emissions) CISPR 24:1997 Class A (International Immunity) IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C |
Country-specific |
VCCI Class A (Japan Emissions) AS/NZS 3548 ACA (Australia Emissions) CNS 13438:1997 Class A (BSMI-Taiwan) MIC Mark, EMC Approval (South Korea) |
ETSI EN 300 386:2001 (EMC Telecommunications) ETSI EN 300 019 (Environmental for Telecommunications) |
IEEE 802.3ab 1000BASE-T |
Environmental standards |
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5G |
Operating conditions |
Temperature range: 0°C to 40°C (32°F to 104°F) Humidity: 10% to 93% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) Shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks Random vibration: 3 to 500 Hz @ 1.5 G rms |
Storage & transportation conditions (packaged) |
Transportation temperature: -40°C to 70°C (-40°F to 158°F) Storage and transportation humidity: 10% to 95% relative humidity, non-condensing Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged sine vibration: 5 to 62 Hz @ velocity 5 mm/s, 62 to 500 Hz @ 0.2 G Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz 14 drops minimum on sides & corners @ 42 inches (<15 kg box) |
Acoustic sound |
Sound Power in accordance with EN 300 753 (10-1997) Sound power: 62 dBA per ISO 7779 Declared sound power: 6.4 belsA per ISO 7779 & ISO 9296 Bystander Sound Pressure in accordance with NEBS GR-63 Issue 2 Bystander sound pressure: 54 dBA right side @ 0.6 m |