VX-RPS-1000 Redundant Power Supply

Tip

Tip

Extreme Redundant Power Supplies (RPS) do not support the ability for the RPS to be connected to an operational switch. Connecting an RPS to an operational switch can have an adverse effect on the switch. It is best practice that both the switch and the RPS be powered down prior to cabling them together. Once the cabling is completed, turn on the RPS, then turn on the switch.

The VX-RPS-1000 provides load sharing, backup, or additive power for the V400 Virtual Port Extender.

Click to expand in new window
VX-RPS-1000 Front Panel
1 = Captive screws 3 = Connector to port extender
2 = Status LEDs 4 = AC power input connector
Table 1. VX-RPS-1000 LED Status Definitions
LED LED Color Status
AC OK Green AC input within operational range
Off No AC voltage or AC voltage is outside the operational range
DC OK Green DC input within operational range
Off No DC voltage or DC voltage is outside the operational range

For technical specifications, including pin locations and functions, see #GUID-E9E4F3AF-334B-4598-9567-A5E75E049651.