The following tools and materials are required to install a non-PoE V300 Virtual Port
                Extender to a single rack mount:
            
                - ESD-preventive wrist strap
- M4 #2 Phillips screwdriver
                    (magnetic screwdriver recommended)
- XN-2P-RMTKIT-1CS-001 - Single
                    rack mount kit
 
        - 
                Remove all contents of the
                    single rack mount kit (XN-2P-RMTKIT-1CS-001).
            
- 
                Attach the short and long ear
                    brackets to the V300 using the screws provided.
            
- 
                Secure the bracket flanges to
                    the rack using the customer-provided screws appropriate for the rack you are
                    using.
            
- 
                After attaching the PSU bracket to the V300, attach the PSU to the PSU mounting
                    brackets using two or four cable ties:
                
                    V300-8P-2X Single Rack Mounting with PSU V300HT-8P/8T-2X Single Rack Mounting with PSUs 
 
- 
                For a more secure attachment, attach the two PSU mounting brackets to the rack
                    using customer-provided screws:
                
                    V300HT-8P/8T-2X Single Rack Mounting with DIN Rail and PSUs 
 
- 
                Alternatively, the PSU can be mounted to the long rack ear using cable
                    ties.