Summit X250e-24tDC Switch Ports and Slots 
    
     
    
        The front panel of the Summit X250e-24tDC switch includes:
        
            Twenty-four fixed autosensing 10/100BASE-T ports (ports
                    1–24) that provide 2.4 Gbps of high-density copper connectivity.
             
            Two combination ports (ports 25–26) using RJ45 connectors and
                SFPs to provide 2 Gbps of copper or fiber connectivity. For
                    more information about combination ports, see Combination Ports and Failover .
                For information about SFPs, see the Extreme Networks
								Pluggable Transceivers Installation Guide 
             
            LEDs to indicate port status and switch operating conditions. For a description of the LEDs and their operation, see Summit X250e Series Switch LEDs .
             
            Stack number indicator showing the position of this switch in a
                stacked configuration. 
            Serial console port used to connect a terminal and perform local
                management. 
         
        Summit X250e-24tDC Switch Front Panel 
            
            
        The rear panel of the Summit X250e-24tDC switch (shown in 
Summit X250e-24tDC Switch Rear Panel ) includes:
                Ethernet management port with associated LEDs. 
                Two high-performance stacking ports with associated
                    LEDs. 
                Redundant power input connector for optional connection to
                    the EPS-150DC External Power Module (Model No. 10909). The
                        connecting redundant power supply cable is shipped with the EPS-150DC unit.
                        See EPS-150DC External Power Module (with EPS-T2)  for more information. 
                 
                DC power input socket. The internal
                        power supply operates from -36 VDC to -72 VDC.
                 
                Grounding lug.
                 
             
            Note    
For centralized DC power connection, this
                product is intended to be installed in a restricted access location (such as a
                dedicated equipment room, equipment closet, or central office) in accordance with
                Articles 110-16, 110-17, and 110-18 of the National Electric Code, ANSI/NFPA
                70.
Summit X250e-24tDC Switch Rear Panel