Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50 to 60 Hz, 10 A |
Input Current |
6 A at 100 V, 2.5 A at 240 V |
Line frequency range |
47 to 63 Hz |
Maximum inrush current |
30 A at 115 V, 60 A at 230 V |
Output |
-50 V, 7.5 A max, 375 Watts 12 V, 7.5 A max, 90 Watts |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
>75% at 100% load |
Heat dissipation, Watts, BTU/hr |
123 W, 419.7 BTU/hr |
Power consumption, Watts, BTU/hr |
588 W, 2006.3 BTU/hr |
Ambient operating temperature |
0°C to 40°C (32°F to 104°F) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 250 V, 4 to 2 A, 47 to 63 Hz |
Line frequency range |
47 to 63 Hz |
Input current |
2 A at 100 V 1 A at 240 V |
Line frequency |
50 to 60 Hz |
Maximum inrush current |
30 A at 115 V, 50 A at 230 V |
Output |
12 V, 11 A 5 V, 1.5 A |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power supply input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
80% at 100% load |
Heat dissipation, Watts/BTU |
38.5 W, 131.4 BTU/hr |
Power consumption, Watts, BTU/hr |
178 W, 607.4 BTU/hr |
Ambient operating temperature |
0°C to 40°C (32°F to 104°F) |
Connector | Pin Number | Wire Label | Pin Number | Wire Label |
---|---|---|---|---|
1 |
NC |
8 |
RS+ |
|
2 |
GND |
9 |
GND |
|
3 |
GND |
10 |
INT PG |
|
4 |
GND |
11 |
EXT_CON |
|
5 |
GND |
12 |
EXT_PG |
|
6 |
+12 V |
13 |
+5 V |
|
7 |
+12 V |
14 |
+12 V |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100 to 240 V, 50 to 60 Hz, 10 A |
Nominal input current |
5.75 A @ 115 V (low-line) 2.80 A @ 230 V (high-line) |
Line frequency range |
47 to 63 Hz |
Maximum inrush current |
30 A @ 115 V, 60 A @ 220 V |
Output |
-50 V, 7.5 A max, 375 Watts 12 V, 10.5 A max, 126 Watts Maximum continuous DC output shall not exceed 500 Watts. |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
>70% @ 100% load |
Heat dissipation, Watts, BTU/hr |
158 W, 539.1 BTU/hr |
Power consumption, Watts, BTU/hr |
659 W, 2248.6 BTU/hr |
Ambient operating temperature |
0°C to 40°C (32°F to 104°F) |
Operational voltage range |
90 to 264 V |
Nominal input ratings |
100-250 V, 50/60 Hz, 10 A |
Nominal input current |
7 A @ 115 V (low-line) 3.5 A @ 230 V (high-line) |
Line frequency range |
47 to 63 Hz |
Maximum inrush current |
17 A @ 115 V/60 Hz, maximum load |
Output power |
600 W |
Power supply cord type |
AC |
Power supply input socket |
IEC 320 C14 |
Power cord input plug |
IEC 320 C13 |
Power cord wall plug |
Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. |
Power supply cord gauge |
18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet |
Efficiency |
85% nominal |
Heat dissipation, Watts, BTU/hr |
219 W, 747.3 BTU/hr |
Power consumption, Watts, BTU/hr |
801 W, 2733.1 BTU/hr |
Ambient operating temperature |
0°C to 40°C (32°F to 104°F) |
Output Ratings for EPS-C chassis with 1, 2, or 3 installed EPS-600LS units |
|
One EPS-600-LS unit |
582 W output: –48 V/9 A (432 W), 12 V/12.5 A |
Two EPS-600-LS units |
1116 W output: –48 V/18 A (864 W), 12 V/21 A |
Three EPS-600-LS units |
1260 W output: –48 V/21 A (1008 W), 12 V/21 A |
Operational voltage range |
–36 to –72 V |
Nominal input ratings |
–36 to –72 V, 6 A maximum |
Input current |
5.5 A @ –36 V (low-line) 2.6 A @ –72 V (high-line) |
Line frequency range |
47 to 63 Hz |
Inrush current |
20 A @ 48 V, 40 A @ 72 V |
Input wire harness |
Extreme part number 250088-00 |
Power supply input socket |
TYCO PN 206061-1 |
Power cord input plug |
TYCO PN 206060-1 |
Power cord wall plug |
None provided |
Power supply cord gauge |
14 AWG (2.0 mm2) |
Input wire harness |
Extreme part number250088-00 |
Efficiency |
> 75% at 100% load |
Heat dissipation, Watts, BTU/hr |
45 W, 153.5 BTU/hr |
Power consumption, Watts, BTU/hr |
195 W, 665.4 BTU/hr |
Ambient operating temperature |
0°C to 40°C |
Storage and transportation temperature |
–40°C to 70°C |
Pin Number | Wire Color | Circuit Connection |
---|---|---|
1 |
Green/yellow |
Chassis ground |
2 |
Red |
Return |
3 |
Black |
-48 V |
4 |
unused |