This section describes how to install versatile interface modules
(VIMs).
You need the following tools and materials to install a VIM:
- ESD-preventive wrist strap
- #1 Phillips screwdriver
Caution
Summit VIMs are not hot-swappable. Disconnect power to
the switch before removing an installed VIM or installing a new
VIM.
The installation procedure is the same for all VIMs attached to
Summit X480, X650, and X670 series switches.
To install a VIM, follow these steps:
-
Attach an ESD-preventive wrist strap to your wrist
and connect the metal end to an appropriate ground point on the rack.
-
Disconnect the switch power.
-
Remove the cover plate from the VIM slot:
-
Remove the retaining screws at the top
corners of the cover plate or module, and set the screws aside in a safe
place.
-
Save the retaining screws to secure the
new module in the switch.
-
Pull the cover plate away from the module
slot.
-
Remove the new VIM from its anti-static
packaging.
-
Install the VIM in the switch (see Installing a Versatile Interface
Module):
-
Make sure the inserter/ejector levers are
rotated down.
-
Carefully slide the module into the switch
until the inserter/ejector levers begin to rotate upward.
-
Simultaneously rotate both levers upward
to seat the module internal connectors.
-
Insert and tighten the retaining screws
you removed earlier.