Use the MBO-ART03 articulating
mounting bracket with the ACC-MBO-KT-AX Adapter for wall installations.
About this task
![Note](images/note.png)
Note
This task only applies to the
AP460C,
AP460C,
AP460S6C and
AP460S12C.
The following hardware is required for outdoor access point wall
installation using the -MBO adapter and MBO-ART03 articulating mounting bracket:
- One outdoor access point
- One ACC-MBO-KT-AX
adapter
- Two M5 hex bolts
- One MBO-ART03 articulating
mounting bracket
- Four M6 hex-head screws
In addition, you need a torque wrench, a drill and a
carpenter's pencil or a pen. Attach the access point to a wall using the -MBO adapter
with the MBO-ART03 articulating mounting bracket.
![Note](images/note.png)
Note
When using the MBO-ART03
articulating mounting bracket, set the maximum downward tilt to less than 20
degrees to prevent water ingress.
Procedure
-
Attach the ACC-MBO-KT-AX adapter
to the access point using the two M5 bolts.
-
Torque the M5 bolts to 25 in-lbs.
-
Use the MBO-ART03 articulating mounting bracket as a template, mark and drill
two holes on the wall.
-
Attach the larger face plate end of the MBO-ART03 mounting bracket to the
ACC-MBO-KT-AX adapter using two M6 hex-head screws.
-
Align the mounting holes on the ART03 bracket against the holes on the
wall.
-
Attach the ART03 bracket to the wall using two M6 hex-head screws.