Auto-sense Port Configuration using EDM
Perform the following procedures to configure Auto-sense on specific ports using the Enterprise Device Manager (EDM).
Enable Auto-sense on Port(s)
About this task
Perform this procedure to enable Auto-sense on one or more ports.
If you select more than one port, the format of the tab changes to a table-based tab.
Note
- After a switch boots without a configuration file, Auto-sense is enabled on all ports, by default.
- Auto-sense is disabled by default for existing configurations but enabled for new Zero Touch Fabric Configuration deployments.
Procedure
- In the Device Physical View tab, select one or more ports.
- In the navigation pane, expand .
- Select General.
- Select the Interface tab.
- For AutoSense, select enable.
- Select Apply.
Disable Auto-sense on Port(s)
About this task
Perform this procedure to disable Auto-sense on one or more ports. You also have the option to disable Auto-sense on the port but retain the configuration that the system applied dynamically. The dynamic configuration becomes a manual configuration and is visible in the show running-config output.
If you select more than one port, the format of the tab changes to a table-based tab.
Procedure
- In the Device Physical View tab, select one or more ports.
- In the navigation pane, expand .
- Select General.
- Select the Interface tab.
- For AutoSense, select disable.
- Optional: Select AutoSenseKeepAutoConfig to retain the configuration that the system applies dynamically.
- Select Apply.
Configure an Auto-sense Data I-SID on a Port
About this task
Perform this procedure to configure an Auto-sense Data I-SID on a port.
Procedure
- In the Device Physical View tab, select a port.
- In the navigation pane, expand .
- Select General.
- Select the Interface tab.
- For AutoSenseDataIsid, type the data I-SID value. The range is 0 to 15999999.
- Select Apply.