View DDI Port Information
Perform this procedure to view basic manufacturing information and characteristics, and the current configuration.
About this task
This command displays information for DDI transceivers.
Note
Transceiver support differs across hardware platforms. For information about supported parts, see Extreme Optics website.
Procedure
Examples
Switch:1#show pluggable-optical-modules config ================================================================================ Pluggable Optical Module Global Configuration ================================================================================ ddm-monitor : disabled ddm-monitor-interval : 5 ddm-traps-send : enabled ddm-alarm-portdown : disabled
The following example includes Extreme extended diagnostic information. Not all parts support this information. A value of 254 indicates the part has not been initialized.
Switch:1#show pluggable-optical-modules detail 1/29 ================================================================================ Pluggable Optical Module Info 1/29 Detail ================================================================================ Port: 1/29 Type: 40GbSR4 DDM Supported : TRUE Vendor Name : EXTREME NETWORKS Partnumber : EQPT404SR4VCM100 Vendor REV : A Vendor SN : 18260006CNFN01 Vendor Date : 06/26/18 Wavelength : 850.00 nm Digital Diagnostic Interface Supported Optics Status : Ok Calibration : Internal RX Power Measurement : Average Auxiliary 1 Monitoring : Not Implemented Auxiliary 2 Monitoring : Not Implemented --------------------------------------------------------------------------------------- LOW_ALARM LOW_WARN ACTUAL HIGH_WARN HIGH_ALARM THRESHOLD THRESHOLD THRESHOLD VALUE THRESHOLD THRESHOLD STATUS --------------------------------------------------------------------------------------- Temp(C) -5.0 0.0 31.3710 70.0 75.0 Normal Voltage(V) 2.9700 3.1000 3.2996 3.4650 3.6300 Normal Tx1Bias(mA) 2.0 3.0 7.6800 13.0 14.0 Normal Tx2Bias(mA) 2.0 3.0 7.5520 13.0 14.0 Normal Tx3Bias(mA) 2.0 3.0 7.6800 13.0 14.0 Normal Tx4Bias(mA) 2.0 3.0 7.4240 13.0 14.0 Normal Tx1Power(dBm) -11.3000 -7.3000 -2.6000 0.0 3.0 Normal Tx2Power(dBm) -11.3000 -7.3000 -2.5000 0.0 3.0 Normal Tx3Power(dBm) -11.3000 -7.3000 -2.9000 0.0 3.0 Normal Tx4Power(dBm) -11.3000 -7.3000 -2.7000 0.0 3.0 Normal Rx1Power(dBm) -13.9000 -9.9000 -4.1000 0.0 3.0 Normal Rx2Power(dBm) -13.9000 -9.9000 -3.4000 0.0 3.0 Normal Rx3Power(dBm) -13.9000 -9.9000 -2.9000 0.0 3.0 Normal Rx4Power(dBm) -13.9000 -9.9000 -3.2000 0.0 3.0 Normal Extreme Extended Diagnostic Information --------------------------------------------------------------------------------------- Power On Counter (48 hours) : 5 Tx1 DDM Initial (dBm) : 7 Tx1 DDM Last Gasp (dBm) : 7 Tx2 DDM Initial (dBm) : 7 Tx2 DDM Last Gasp (dBm) : 7 Tx3 DDM Initial (dBm) : 7 Tx3 DDM Last Gasp (dBm) : 7 Tx4 DDM Initial (dBm) : 6 Tx4 DDM Last Gasp (dBm) : 6 Rx1 DDM Initial (dBm) : 254 Rx1 DDM Last Gasp (dBm) : 254 Rx2 DDM Initial (dBm) : 254 Rx2 DDM Last Gasp (dBm) : 254 Rx3 DDM Initial (dBm) : 254 Rx3 DDM Last Gasp (dBm) : 254 Rx4 DDM Initial (dBm) : 254 Rx4 DDM Last Gasp (dBm) : 254
Variable Definitions
Use the data in the following table to use the show pluggable-optical-modules basic and show pluggable-optical-modules detail commands.
Variable |
Value |
---|---|
{slot/port[/sub-port] [-slot/port[/sub-port]] [,...]} |
Identifies the slot and port in one of the following formats: a single slot and port (slot/port), a range of slots and ports (slot/port-slot/port), or a series of slots and ports (slot/port,slot/port,slot/port). If the platform supports channelization and the port is channelized, you must also specify the sub-port in the format slot/port/sub-port. |