Configure the IPFIX Collector
About this task
Use the following procedure to configure a collector for IPFIX. Use the ExtremeAnalytics™ solution as the collector.
Procedure
- In the navigation pane, expand .
- Select IPFIX.
- Select the Collector tab.
- Click Insert.
- In the Num field, specify a value for the collector ID number.
- In the AddressType field, specify a value for the IP address type of the collector.
- In the Address field, specify a value for the IP address of the collector.
- Optional: In the SrcPort field, specify a value for the source port sending flow information.
- Optional: In the DestPort field, specify a value for the destination port receiving flow information.
- In the ExporterIpType field, specify a value for the IP address type of the exporter for the collector.
- In the ExporterIp field, specify the IP address of the exporter for the collector.
- Optional: In the ExportInterval field, specify the frequency of template packets exports to the collector.
- Optional: In the InitialBurst field, specify the number of template packets to send when the collector becomes reachable.
- Select Insert.
Collector Field Descriptions
Use the data in the following table to use the Collector tab.
Name |
Description |
---|---|
Num |
Specifies the ID number of the collector |
AddressType |
Specifies the IP address type of the collector. |
Address |
Specifies the IP address of the collector. |
Protocol |
Specifies the protocol used to export data from the exporter to the collector. |
SrcPort |
Specifies the source port sending flow information. The default value is 2055. |
DestPort |
Specifies the destination port receiving flow information. The default value is 2055. |
ExporterIpType |
Specifies the IP address type of the exporter for the collector. |
ExporterIp |
Specifies the IP address of the exporter for the collector. |
State |
Specifies the state of the collector. The default value is enabled. |
IsReachable |
Specifies whether the collector is reachable. The default value is false (not reachable) |
ViaNextHopName |
Specifies the next-hop through which the collector is reachable. |
ExportInterval |
Specifies, in seconds, the frequency of template packets exports to the collector. The default value is 60 seconds. |
InitialBurst |