View DDI Information
About this task
You can view DDI information, for example, port information, temperature, and voltages for DDI transceivers.
Note
Transceiver support differs across hardware platforms. For information about supported parts, see Extreme Optics website.
Procedure
- On the Physical Device view, select one or more ports.
- In the navigation pane, expand .
- Select General.
- Select the DDI/SFP tab.
DDI/SFP Field Descriptions
Use the data in the following table to use the DDI/SFP tab.
Name |
Description |
---|---|
ConnectorType |
Indicates the type of connector. |
SupportsDDM |
Indicates if the transceiver supports DDM. |
DdmStatusMask |
Indicates the DDM status. A value other than ddm-ok represents a specific error. |
CLEI |
Indicates the Telcordia register assignment CLEI code. |
VendorName |
Indicates the name of the manufacturer. |
VendorPartNumber |
Indicates the part number for the transceiver. |
VendorRevNumber |
Indicates the manufacturer revision level for the transceiver. |
VendorSN |
Indicates the manufacturer serial number for the transceiver. |
VendorDateCode |
Indicates the manufacturer date code for the transceiver. |
Wavelength |
Indicates the wavelength in nm. This field is valid for optical transceivers only. |
Calibration |
Indicates if the calibration is internal or external. |
PowerMeasure |
Indicates Rx power measurement as average or OMA. |
Aux1Monitoring |
Indicates if auxiliary monitoring is implemented for the transceiver. |
Aux2Monitoring |
Indicates if auxiliary monitoring is implemented for the transceiver. |
TemperatureLowAlarmThreshold |
Indicates the low alarm threshold in degrees Celsius. |
TemperatureLowWarningThreshold |
Indicates the low warning threshold in degrees Celsius. |
Temperature |
Indicates the current temperature in degrees Celsius of the transceiver. |
TemperatureHighWarningThreshold |
Indicates the high warning threshold in degrees Celsius. |
TemperatureHighAlarmThreshold |
Indicates the high alarm threshold in degrees Celsius. |
TemperatureStatus |
Indicates if any temperature thresholds were exceeded. |
VoltageLowAlarmThreshold |
Indicates the low alarm threshold in volts. |
VoltageLowWarningThreshold |
Indicates the low warning threshold in volts. |
Voltage |
Indicates the current voltage in volts. |
VoltageHighWarningThreshold |
Indicates the high warning threshold in volts. |
VoltageHighAlarmThreshold |
Indicates the high alarm threshold in volts. |
VoltageStatus |
Indicates if any voltage thresholds were exceeded. |
BiasLowAlarmThreshold |
Indicates the bias current low alarm threshold in mA. |
BiasLowWarningThreshold |
Indicates the bias current low warning threshold in mA. |
Bias |
Indicates the laser bias current in mA. |
BiasHighWarningThreshold |
Indicates the bias current high warning threshold in mA. |
BiasHighAlarmThreshold |
Indicates the bias current high alarm threshold in mA. |
BiasStatus |
Indicates if any bias thresholds were exceeded. |
TxPowerLowAlarmThreshold |
Indicates the low alarm threshold in dBm for the Tx power. |
TxPowerLowWarningThreshold |
Indicates the low warning threshold in dBm for the Tx power. |
TxPower |
Indicates the current Tx power in dBm. |
TxPowerHighWarningThreshold |
Indicates the high warning threshold in dBm for the Tx power. |
TxPowerHighAlarmThreshold |
Indicates the high alarm threshold in dBm for the Tx power. |
TxPowerStatus |
Indicates if any Tx power thresholds were exceeded. |
RxPowerLowAlarmThreshold |
Indicates the low alarm threshold in dBm for the Rx power. |
RxPowerLowWarningThreshold |
Indicates the low warning threshold in dBm for the Rx power. |
RxPower |
Indicates the current Rx power in dBm. |
RxPowerHighWarningThreshold |
Indicates the high warning threshold in dBm for the Rx power. |
RxPowerHighAlarmThreshold |
Indicates the high alarm threshold in dBm for the Rx power. |
RxPowerStatus |
Indicates if any Rx power thresholds were exceeded. |
Aux1LowAlarmThreshold |
Indicates the low alarm threshold auxiliary 1 reading. |
Aux1LowWarningThreshold |
Indicates the low warning threshold auxiliary 1 reading. |
Aux1 |
Indicates the current auxiliary 1 reading. |
Aux1HighWarningThreshold |
Indicates the high warning threshold auxiliary 1 reading. |
Aux1HighAlarmThreshold |
Indicates the high alarm threshold auxiliary 1 reading. |
Aux1Status |
Indicates if any auxiliary 1 thresholds were exceeded. |
Aux2LowAlarmThreshold |
Indicates the low alarm threshold auxiliary 2 reading. |
Aux2LowWarningThreshold |
Indicates the low warning threshold auxiliary 2 reading. |
Aux2 |
Indicates the current auxiliary 2 reading. |
Aux2HighWarningThreshold |
Indicates the high warning threshold auxiliary 2 reading. |
Aux2HighAlarmThreshold |
Indicates the high alarm threshold auxiliary 2 reading. |
Aux2Status |
Indicates if any auxiliary 2 thresholds were exceeded. |
PowerOnCounter |
Tracks the power-on-life of the part. This value increments by 1 every 48 hours of consecutive power. This value is never decremented or cleared. If you remove or reinsert the part, reset or reboot the chassis, reset the slot, or channelize or dechannelize the port, then the 48-hour time period restarts. |
TxDdmInitial |
Indicates the Tx dB from low alarm, which is the difference between the TxPower dBm and the TxPower low alarm. The host provides the value after the first 48 consecutive hours of operation. |
TxDdmLastGasp |
Indicates the last gasp of Tx dB from low alarm. The host updates this value every 48 hours. |
RxDdmInitial |
Indicates the Rx dB from low alarm, which is the difference between the RxPower dBm and the RxPower low alarm. The host provides the value after the first 48 consecutive hours of operation after a power cycle. |
RxDdmLastGasp |
Indicates the last gasp of Rx dB from low alarm. The host updates this value every 48 hours. |
ExtremeExtraFeatures |
Indicates if the device supports the extra Extreme features. |
Note
-
Threshold and actual values for TxBias, TxPower, and RxPower are provided for all 4 channels in QSFP+ and QSFP28 optical transceivers.
-
Auxiliary monitoring does not apply to QSFP+s or QSFP28s.