Summit X250e-24xDC Switch Ports and Slots 
    
     
    
        The front panel of the Summit X250e-24xDC switch includes:
        
            Twenty-four 100BASE-FX ports (ports 1–24) that provide 2.4
                    Gbps of high-density fiber connectivity.
             
            Two combination ports (ports 25–26) using RJ45 connectors and
                    SFPs to provide 2 Gbps of copper or fiber connectivity.
                For more information about combination ports, see Combination Ports and Failover .
                For information about SFPs, see the Extreme Networks
								Pluggable Transceivers Installation Guide  .
             
            LEDs to indicate port status and switch operating
                    conditions.
                For a description of the LEDs and their operation, see Summit X250e Series Switch LEDs .
             
            Stack number indicator showing the position of this switch in
                    a stacked configuration.
             
            Serial console port used to connect a terminal and perform
                    local management. 
             
         
        Summit X250e-24xDC Switch Front Panel 
            
            
         
        The rear panel of the Summit X250e-24xDC switch (
Summit X250e-24xDC Switch Rear Panel ) includes:
                Ethernet management port with associated LEDs.
                 
                Two high-performance stacking ports with associated
                        LEDs.
                 
                Redundant power input connector for use with the EPS-150DC
                        External Power Module (Model No. 10909).
                    The connecting redundant power supply cable is shipped
                        with the EPS-150DC unit. See EPS-150DC External Power Module (with EPS-T2)  for more information.
                 
                DC power input socket.
                    The internal power supply operates from -36 VDC to -72 V
                        DC.
                 
                Grounding lug.
                 
             
         
        Note    
For centralized DC power connection, this product is
            intended to be installed in a restricted access location (such as a dedicated equipment
            room, equipment closet, or central office) in accordance with Articles 110-16, 110-17,
            and 110-18 of the National Electric Code, ANSI/NFPA 70.
 
        Summit X250e-24xDC Switch Rear Panel