The Summit X250e series includes the following switches:
| Summit X250e-24t switch Summit X250e-24tDC switch Summit X250e-24p switch Summit X250e-24x switch Summit X250e-24xDC switch  | 
                            Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 12.13 inches (30.8 cm)  | 
                        
| Summit X250e-48t switch  Summit X250e-48tDC Summit X250e-48p switch  | 
                            Height: 1.73 inches (4.4 cm) Width: 17.35 inches (44.1 cm) Depth: 15.28 inches (38.8 cm)  | 
                        
| Summit X250e-24t switch | 10.5 lb (4.8 kg) | 
| Summit X250e-24tDC switch | 9.9 lb (4.5 kg) | 
| Summit X250e-24p switch | 121.1 lb (5.5 kg) | 
| Summit X250e-24x switch | 10.2 lb (4.6 kg) | 
| Summit X250e-24xDC switch | 10 lb (4.6 kg) | 
| Summit X250e-48t switch | 12.1 lb (5.5 kg) | 
| Summit X250e-48tDC switch | 12.1 lb (5.5 kg) | 
| Summit X250e-48p switch | 12.1 lb (5.5 kg) | 
| Summit X250e-24t switch  Summit X250e-24tDC switch Summit X250e-24p switch Summit X250e-24x switch Summit X250e-24xDC switch  | 
                            Height: 12.6 inches (32 cm) Width: 23.6 inches (60 cm) Depth: 18.5 inches (47 cm)  | 
                        
| Summit X250e-48t switch  Summit X250e-48tDC switch Summit X250e-48p switch  | 
                            Height: 12.2 inches (31 cm) Width: 22.8 inches (58 cm) Depth: 22 inches (56 cm)  | 
                        
| Summit X250e-24t switch  Summit X250e-24x switch  | 
                            13.2 lb (6.0 kg) | 
| Summit X250e-24tDC switch | 13.1 lb (6.0 kg) | 
| Summit X250e-24xDC switch | 13.2 lb (6.0 kg) | 
| Summit X250e-24p switch | 14.9 lb (6.8 kg) | 
| Summit X250e-48t switch | 15.1 lb (6.9 kg) | 
| Summit X250e-48tDC switch | 15.5 lb (7.0 kg) | 
| Summit X250e-48p switch | 17.0 lb (7.7 kg) | 
| Operational voltage range | 90 to 264 V | 
                        
| Nominal input ratings | 100 to 240 V | 
                        
| Input current | 0.5 A @ 115 V 0.25 A @
                                    230 V  | 
                        
| Line frequency range | 47 to 63 Hz | 
| Inrush current | 30 A @ 115 V, 60 A @ 230 V | 
| Power supply cord type | AC | 
| Power supply input socket | IEC 320 C14 | 
| Power cord input plug | IEC 320 C13 | 
| Power cord wall plug | Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. | 
| Power supply cord gauge | 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet  | 
                        
| Efficiency | 83% at 60% to 100% load | 
| Heat dissipation (Watts, BTU) | 36 W (122.8 BTU/hr) | 
| Power consumption (Watts, BTU) | 36 W (122.8 BTU/hr) | 
| Operational voltage range | 90 to 264 V | 
                        
| Nominal input ratings | 100 to 240 V | 
                        
| Input current (without PoE\) | 0.75 A @ 115 V 0.5 A @
                                    230 V  | 
                        
| Input current (with PoE full load) | 4.4 A @ 115 V 2.2 A @
                                    230 V  | 
                        
| Line frequency range | 47 to 63 Hz | 
| Inrush current | 30 A @ 115 V, 60 A @ 230 V | 
| Power supply cord type | AC | 
| Power supply input socket | IEC 320 C14 | 
| Power cord input plug | IEC 320 C13 | 
| Power cord wall plug | Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies. | 
| Power supply cord gauge | 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet  | 
                        
| Efficiency | 81% with 60% to 100% load | 
| Heat dissipation (without PoE) | 75W (256 BTU/hr) | 
| Power consumption (without PoE) | 75 W (256 BTU/hr) | 
| Heat dissipation (with PoE full load) | 130 W (444 BTU/hr) | 
| Power consumption (with PoE full load) | 525 W (1,791 BTU/hr) | 
| Operational voltage range | 90 to 264 V | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 100 to 240 V  | 
                        
| 
                                 Input current  | 
                            
                                 1.0 A @ 115 V 0.5 A @ 230 V  | 
                        
| 
                                 Line frequency range  | 
                            
                                 47 to 63 Hz  | 
                        
| 
                                 Inrush current  | 
                            
                                 30 A @ 115 V, 60 A @ 230 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 AC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 IEC 320 C14  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 IEC 320 C13  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies.  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet  | 
                        
| 
                                 Efficiency  | 
                            
                                 80% with 60% to 100% load  | 
                        
| 
                                 Heat dissipation  | 
                            
                                 49 W (167.2 BTU/hr)  | 
                        
| 
                                 Power consumption  | 
                            
                                 49 W (167.2 BTU/hr)  | 
                        
| Operational voltage range | 
                                 -40 to -72 V  | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 -48 V  | 
                        
| 
                                 Input current  | 
                            
                                 1.25 A at -40 V 0.75 A at -72 V  | 
                        
| 
                                 Inrush current  | 
                            
                                 20 A at -48 V 30 A at -72 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 DC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 TYCO 206061-1  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 TYCO 206060-1  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 None provided  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 14 AWG (2.0 mm2)  | 
                        
| 
                                 Efficiency  | 
                            
                                 83%  | 
                        
| 
                                 Heat dissipation  | 
                            
                                 42 W (143.3 BTU/hr)  | 
                        
| 
                                 Power consumption (Watts)  | 
                            
                                 47 W (160.4 BTU/hr)  | 
                        
| Operational voltage range | 
                                 -40 to -72 V  | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 -48 V  | 
                        
| 
                                 Input current  | 
                            
                                 0.8 A at -40 V 0.5 A at -72 V  | 
                        
| 
                                 Inrush current  | 
                            
                                 20 A at 48 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 DC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 TYCO 206061-1  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 TYCO 206060-1  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 None provided  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 14 AWG (2.0 mm2)  | 
                        
| 
                                 Efficiency  | 
                            
                                 78%  | 
                        
| 
                                 Heat dissipation  | 
                            
                                 31 W (105.8 BTU/hr)  | 
                        
| 
                                 Power consumption (Watts)  | 
                            
                                 31 W (105.8 BTU/hr)  | 
                        
| Operational voltage range | 
                                 90 to 264 V  | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 100 to 240 V  | 
                        
| 
                                 Input current  | 
                            
                                 0.6 A @ 115 V 0.3 A @ 230 V  | 
                        
| 
                                 Line frequency range  | 
                            
                                 47 to 63 Hz  | 
                        
| 
                                 Inrush current  | 
                            
                                 30 A @ 115 V, 60 A @ 230 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 AC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 IEC 320 C14  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 IEC 320 C13  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies.  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet  | 
                        
| 
                                 Efficiency  | 
                            
                                 83% with 60% to 100% load  | 
                        
| 
                                 Heat dissipation (Watts)  | 
                            
                                 51 W (174 BTU/hr)  | 
                        
| 
                                 Power consumption (Watts)  | 
                            
                                 51 W (174 BTU/hr)  | 
                        
| Operational voltage range | 
                                 90 to 264 V  | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 100 to 240 V  | 
                        
| 
                                 Input current with PoE full load  | 
                            
                                 4.5 A @ 115 V 2.25 A @ 230 V  | 
                        
| 
                                 Input current without PoE  | 
                            
                                 0.75 A @ 115 V 0.5 A @ 230 V  | 
                        
| 
                                 Line frequency range  | 
                            
                                 47 to 63 Hz  | 
                        
| 
                                 Inrush current  | 
                            
                                 30 A @ 115 V, 60 A @ 230 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 AC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 IEC 320 C14  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 IEC 320 C13  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 Refer to Power Cord Requirements for AC-Powered Switches and AC Power Supplies.  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 18 AWG (0.75 mm2) up to 6 feet or 2 meters or 16 AWG (1.0 mm2) over 6 feet  | 
                        
| 
                                 Efficiency  | 
                            
                                 78% with 60% to 100% load  | 
                        
| 
                                 Heat dissipation with PoE full load  | 
                            
                                 130 W (444 BTU/hr)  | 
                        
| 
                                 Heat dissipation without PoE  | 
                            
                                 75 W (256 BTU/hr)  | 
                        
| 
                                 Power consumption with PoE full load  | 
                            
                                 525 W (1791.4 BTU/hr)  | 
                        
| 
                                 Power consumption without PoE  | 
                            
                                 75 W (256 BTU/hr)  | 
                        
| Operational voltage range | 
                                 -40 to -72 V  | 
                        
| 
                                 Nominal input ratings  | 
                            
                                 -48 V  | 
                        
| 
                                 Input current  | 
                            
                                 1.25 A at -40 V 0.75 A at -57.6 V  | 
                        
| 
                                 Inrush current  | 
                            
                                 20 A @ 48 V  | 
                        
| 
                                 Power supply cord type  | 
                            
                                 DC  | 
                        
| 
                                 Power supply input socket  | 
                            
                                 TYCO 206061-1  | 
                        
| 
                                 Power cord input plug  | 
                            
                                 TYCO 206060-1  | 
                        
| 
                                 Power cord wall plug  | 
                            
                                 None provided  | 
                        
| 
                                 Power supply cord gauge  | 
                            
                                 14 AWG (2.0 mm2)  | 
                        
| 
                                 Efficiency  | 
                            
                                 78%  | 
                        
| 
                                 Heat dissipation  | 
                            
                                 47 W (160.4 BTU/hr)  | 
                        
| 
                                 Power consumption  | 
                            
                                 47 W (160.4 BTU/hr)  | 
                        
| 
                                 North American Safety of ITE  | 
                            
                                 UL 60950-1:2003 1st Ed., Listed Device (US) CSA 22.2#60950-1-03 1st Ed.(Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) IEEE 802.3af 6-2003 Environment A for PoE Applications  | 
                        
| 
                                 European Safety of ITE  | 
                            
                                 EN 60950-1:2001+A11 EN 60825-1+A2:2001 (Lasers Safety) TUV-R GS Mark by German Notified Body 73/23/EEC Low Voltage Directive  | 
                        
| 
                                 International Safety of ITE  | 
                            
                                 CB Report & Certificate per IEC 60950-1:2001 Country Deviations AS/NZX 60950-1 (Australia /New Zealand)  | 
                        
| 
                                 North America EMC for ITE  | 
                            
                                 FCC CFR 47 part 15 Class A (USA) ICES-003 Class A (Canada)  | 
                        
| 
                                 European EMC standards  | 
                            
                                 EN 55022:1998 Class A EN 55024:1998 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 8, 11 EN 61000-3-2,3 (Harmonics & Flicker) ETSI EN 300 386:2001 (EMC Telecommunications) 89/336/EEC EMC Directive  | 
                        
| 
                                 International EMC certifications  | 
                            
                                 CISPR 22:1997 Class A (International Emissions) CISPR 24:1997 Class A (International Immunity) IEC/EN 61000-4-2 Electrostatic Discharge, 8kV Contact, 15kV Air, Criteria A IEC/EN 61000-4-3 Radiated Immunity 10V/m, Criteria A IEC/EN 61000-4-4 Transient Burst, 1kV, Criteria A IEC/EN 61000-4-5 Surge, 2kV L-L, 2kV L-G, Level 3, Criteria A IEC/EN 61000-4-6 Conducted Immunity, 0.15-80MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11 Power Dips & Interruptions, >30%, 25 periods, Criteria C  | 
                        
| 
                                 Country-specific  | 
                            
                                 VCCI Class A (Japan Emissions) AS/NZS 3548 ACA (Australia Emissions) CNS 13438:1997 Class A (BSMI-Taiwan) MIC Mark, EMC Approval (South Korea)  | 
                        
| 
                                 ETSI EN 300 386:2001 (EMC Telecommunications) ETSI EN 300 019 (Environmental for Telecommunications)  | 
                        
| 
                                 IEEE 802.3ab 1000BASE-T  | 
                        
| 
                                 Environmental Standards  | 
                            
                                 EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5G  | 
                        
| 
                                 Operating conditions  | 
                            
                                 Temperature range: 0° C to 40° C (32° F to 104° F) Humidity: 95% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) Shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks Random vibration: 3 to 500 Hz @ 1.5 G rms  | 
                        
| 
                                 Storage & transportation conditions (packaged)  | 
                            
                                 Storage temperature: –40° C to 85° C (–40° F to 185° F) Storage and transportation humidity: 10% to 95% relative humidity, non-condensing Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged sine vibration: 5 to 62 Hz @ velocity 5 mm/s, 62 to 500 Hz @ 0.2 G Packaged random vibration: 5 to 20 Hz @ 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz 14 drops minimum on sides & corners @ 42 inches (<15 kg box)  | 
                        
| Acoustic noise (in dBA per ISO 7779) | 
                                 Summit X250e-24t: 45 (high fan speed) 37 (low fan speed) Summit X250e-24p: 44 (high fan speed) 39 (low fan speed) Summit X250e-24x: 45 (high fan speed) 37 (low fan speed) Summit X250e-24xDC: 47 (high fan speed) 37 (low fan speed) Summit X250e-24tDC: 45 (high fan speed) 37 (low fan speed) Summit X250e-48t: 47 (high fan speed) 37 (low fan speed) Summit X250e-48p: 46 (high fan speed) 39 (low fan speed) Summit X250e-48tDC: 47 (high fan speed) 37 (low fan speed)  |