The following sections describe the meanings of the LEDs on the Summit X650 series switches.
| Label or Type | Color/State | Meaning | 
|---|---|---|
| MGMT | Blinking green | Normal operation | 
| Blinking amber | Power-on self test (POST) failed; diagnostic test in progress. | |
| Off | No external power is attached. | |
| FAN | Steady green | Normal operation | 
| Blinking amber | Failure | |
| Off | No power | |
| PSU-1 | Steady green | Normal operation | 
| Blinking amber | Failure | |
| Off | No power | |
| PSU-2 | Steady green | Normal operation | 
| Blinking amber | Failure | |
| Off | No power | |
| Stack 1 – 4 | Steady green | Link OK on the indicated stacking port. | 
| 
                                 Blinking green  | 
                            
                                 Activity on the indicated stacking port.  | 
                        
| Label or Type | Color/State | Meaning | 
|---|---|---|
| Left digit (1) | Reserved for future use. | |
| Right digit (1 – 8) | Indicates the position of this switch in the SummitStack configuration. | |
| Upper half blinking | This switch is the stack master node. | |
| Lower half blinking | This switch is the stack backup node. | |
| Lit steadily | This switch is a standby node in the stack. | |
| Ethernet Ports 1 – 24  | 
                            Steady green | Link OK | 
| Blinking green | Activity | |
| Management Port | Steady green | Link OK | 
| Blinking green | Activity | 
| Label or Type | Color/State | Meaning | 
|---|---|---|
| Stacking Port LED (on installed VIM1 module) | Steady green | Link OK | 
| Blinking green | Activity | |
| SFP/SFP+ port LED (on installed VIM1 module) | Steady green | Link OK | 
| Blinking green | Activity |