pluggable-optical-module
Configure Digital Diagnostic Monitoring to get information concerning the status of the
transmitted and received signals to allow better fault isolation and error detection.
Syntax
-
default
pluggable-optical-module ddm-alarm-portdown
-
default
pluggable-optical-module ddm-monitor
-
default
pluggable-optical-module ddm-monitor-interval
-
default
pluggable-optical-module ddm-traps-send
-
no
pluggable-optical-module ddm-alarm-portdown
-
no
pluggable-optical-module ddm-monitor
-
no
pluggable-optical-module ddm-traps-send
-
pluggable-optical-module
ddm-alarm-portdown
-
pluggable-optical-module
ddm-monitor
-
pluggable-optical-module
ddm-monitor-interval <5-60>
-
pluggable-optical-module
ddm-traps-send
-
pluggable-optical-module
reset {slot/port[/sub-port]}
Command Parameters
- ddm-alarm-portdown
- Sets the port down when an alarm
occurs. When enabled, the port goes down when any alarm occurs.
- ddm-monitor
- Enables the monitoring of the
digital diagnostic monitoring (DDM). When enabled, you see the internal
performance condition (temperature, voltage, bias, Tx power and Rx power) of the
pluggable transceiver. The default is disable.
- ddm-monitor-interval <5-60>
- Configures the digital diagnostic
monitoring (DDM) monitor interval in the range of 5 to 60 in seconds. If any alarm
occurs, the user gets the log message before the specific interval configured by
the user. The default value is 5 seconds.
- ddm-traps-send
- Enables or disables the sending of
trap messages. When enabled, the trap message is sent to the Device manager, any
time the alarm occurs. The default is enable.
- reset {slot/port[/sub-port]}
- Reset a transceiver to simulate
removal and reinsertion of the transceiver, which can be helpful in
troubleshooting. For example, if authentication of the transceiver fails, you can
reset the transceiver to begin the authentication process again. Before you use
this command, ensure the port is administratively down to avoid link flaps.
-
Identifies a single slot and port.
If the platform supports channelization and the port is
channelized, you must also specify the sub-port in the format
slot/port/sub-port.
Default
The default is disable.
Command Mode
Global Configuration