raid

Device Config Commands

Enables chassis alarm that sounds when events are detected that degrade RAID support (drive content mirroring) on a service platform

The NX9500 series service platforms include a single Intel MegaRAID controller (virtual drive) with RAID-1 mirroring support enabled. The online virtual drive supports up to two physical drives that could require hot spare substitution if a drive were to fail. The WiNG software allows you to manage the RAID controller event alarm and syslogs supporting the array hardware from the service platform user interface without rebooting the service platform BIOS.

Although RAID controller drive arrays are available only on the NX9500 series service platforms, they can be administrated on behalf of a NX9500 profile by a different model service platform or wireless controller.

Supported in the following platforms:

Syntax

raid alarm enable

Parameters

raid alarm enable
alarm enable Enables audible alarm, which is triggered a RAID drives fails. When triggered the alarm can be disabled by executing the raid > silence command in the device‘s Priv Exec mode.

Example

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#raid alarm enable

nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#show context
nx9000 B4-C7-99-6C-88-09
 use profile default-nx9000
 use rf-domain default
 hostname nx9500-6C8809
 ip default-gateway 192.168.13.2
 interface ge1
  switchport mode access
  switchport access vlan 1
 interface vlan1
  ip address 192.168.13.13/24
 logging on
 logging console warnings
 logging buffered warnings
 raid alarm enable
nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#

Related Commands

no Disables RAID alarm