Enables chassis alarm that sounds when events are detected that degrade RAID support (drive content mirroring) on a service platform
The NX9500 series service platforms include a single Intel MegaRAID controller (virtual drive) with RAID-1 mirroring support enabled. The online virtual drive supports up to two physical drives that could require hot spare substitution if a drive were to fail. The WiNG software allows you to manage the RAID controller event alarm and syslogs supporting the array hardware from the service platform user interface without rebooting the service platform BIOS.
Although RAID controller drive arrays are available only on the NX9500 series service platforms, they can be administrated on behalf of a NX9500 profile by a different model service platform or wireless controller.
raid alarm enable
alarm enable | Enables audible alarm, which is triggered a RAID drives fails. When triggered the alarm can be disabled by executing the raid > silence command in the device‘s Priv Exec mode. |
nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#raid alarm enable nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#show context nx9000 B4-C7-99-6C-88-09 use profile default-nx9000 use rf-domain default hostname nx9500-6C8809 ip default-gateway 192.168.13.2 interface ge1 switchport mode access switchport access vlan 1 interface vlan1 ip address 192.168.13.13/24 logging on logging console warnings logging buffered warnings raid alarm enable nx9500-6C8809(config-device-B4-C7-99-6C-88-09)#
no | Disables RAID alarm |