Note
AC power input cords are not provided with AC power supplies. You can order an appropriate cord from Extreme Networks or from your local supplier. The power cord must meet the requirements listed in Power Cord Requirements for AC-Powered Switches and AC Power Supplies.The power supply must have the same airflow direction (front-to-back or back-to-front) as the switch with which it is being used. In a redundant power configuration, the airflow direction must be the same for both power supplies, and it must match the airflow direction of the fans in the switch.
For information on installing or replacing an AC or DC power supply, see the following topics:
The following tables describe the meanings of the LEDs on the 750 W AC power supply (part number XN-ACPWR-750W-F or XN-ACPWR-750W-R).
The LEDs are located on the end of the power supply unit, arranged vertically to the left of the terminal block.
Label and Color | Description | State | Meaning |
---|---|---|---|
! Amber |
Fault Indicator | On (Solid) | PSU fault |
Off | No PSU fault | ||
DC (Green) |
DC output Good | On (solid) | DC output OK |
Off or Blinking |
DC output fail |
||
AC (Green) |
AC input Good | On | AC input OK |
Off | AC input fail |
The following tables describe the meanings of the LEDs on the 750 W DC power supply (part number XN-DCPWR-750W-F or XN-DCPWR-750W-R).
The LEDs are located on the end of the power supply unit, arranged vertically to the left of the terminal block.
Label and Color | Description | State | Meaning |
---|---|---|---|
! Amber |
Fault Indicator | On (Solid) | PSU fault |
Off | No PSU fault | ||
OUT OK (Green) |
DC output Good | On (solid) | DC output OK |
Off or Blinking |
DC output fail |
||
IN OK (Green) |
DC input Good "IN OK" | On | DC input OK |
Off | DC input fail |