The following V400 Virtual Port Extender models are available:
V400-24t-10GE2 | Height: 1.70 in (4.32 cm) Width: 9.97 in (25.3 cm) Length: 17.34 in (44.0 cm) |
V400-24p-10GE2 | Height: 1.70 in (4.32 cm) Width: 9.97 in (25.3 cm) Length: 17.34 in (44.0 cm) |
V400-48t-10GE4 | Height: 1.70 in (4.32 cm) Width: 9.97 in (25.3 cm) Length: 17.34 in (44.0 cm) |
V400-48p-10GE4 | Height: 1.70 in (4.32 cm) Width: 15.25 in (38.7 cm) Length: 17.34 in (44.0 cm) |
V400-24t-10GE2 | 6.62 lb (3.00 kg) |
V400-24p-10GE2 | 9.08 lb (4.12 kg) |
V400-48t-10GE4 | 7.14 lb (3.26 kg) |
V400-48p-10GE4 | 14.06 lb (6.38 kg) |
V400-24t-10GE2 | Height: 4.49 in (11.4 cm) Width: 14.66 in (37.2 cm) Length: 22.02 in (55.9 cm) |
V400-24p-10GE2 | Height: 4.49 in (11.4 cm) Width: 14.66 in (37.2 cm) Length: 22.02 in (55.9 cm) |
V400-48t-10GE4 | Height: 4.49 in (11.4 cm) Width: 14.66 in (37.2 cm) Length: 22.02 in (55.9 cm) |
V400-48p-10GE4 | Height: 4.49 in (11.4 cm) Width: 19.86 in (50.4 cm) Length: 22.02 in (55.9 cm) |
V400-24t-10GE2 | 9.00 lb (4.08 kg) |
V400-24p-10GE2 | 11.44 lb (5.19 kg) |
V400-48t-10GE4 | 9.69 lb (4.39 kg) |
V400-48p-10GE4 | 16.56 lb (7.50 kg) |
Note
When you use a redundant power supply (RPS), only redundant power – not additive power – is supported. Thus, the PoE ports load does not increase when an RPS is added.V400-24t-10GE2 | AC Input: 100-240 VAC, 50/60 Hz, 0.6 A max |
V400-24p-10GE2 | AC Input: 100-240 VAC, 50/60 Hz, 2.2 A max DC RPS
input: 54 VDC, 18.52 A max
|
V400-48t-10GE4 | AC Input: 100-240 VAC, 50/60 Hz, 1.0 A max |
V400-48p-10GE4 | AC Input: 100-240 VAC, 50/60 Hz, 12.0 - 6.0 A
max DC RPS input: 54 VDC, 18.52 A max
|
Minimum1 Heat Dissipation (BTU/hr) | Minimum1 Power Consumption (Watts) | Maximum1 Heat Dissipation (BTU/hr) | Maximum1 Power Consumption (Watts) | |
---|---|---|---|---|
V400-24t-10GE2 | 36.1 | 10.6 | 75.2 | 22.1 |
V400-24p-10GE2 | 109.8 | 32.2 | 336.8 | 478.7 |
V400-48t-10GE4 | 66.0 | 19.3 | 134.8 | 39.5 |
V400-48p-10GE4 | 168.9 | 49.5 | 583.2 | 910.9 |
VX-RPS-1000 | 141.3 | 41.4 | 3152.8 | 924 |
Bystander Sound Pressure2 in dB(A) | Declared Sound Power (LWAd)2 in bels | |
---|---|---|
V400-24t-10GE2 | 41.6 (Duty 30%) / 59.4 (max.) |
4.4 (Duty 30%) / 6.2 (max.) |
V400-24p-10GE2 | 47.5 (Duty 30%) / 64.0 (max.) |
5.0 (Duty 30%) / 6.7 (max.) |
V400-48t-10GE4 | 43.4 (Duty 30%) / 61.1 (max.) |
4.6 (Duty 30%) / 6.4 (max.) |
V400-48p-10GE4 | 48.5 (Duty 30%) / 65.5 (max.) |
5.1 (Duty 30%) / 6.8 (max.) |
North American Safety of ITE |
UL 60950-1 2nd Ed., A2:2014, Listed Device (US) CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) |
European Safety of ITE |
EN 60950-1:2006 +A11+A1+A12+A2 EN 60825-1:2007 (Lasers Safety) IEC 60950-1:2005 2nd+A1:2009+A2:2013 2014/35/EU Low Voltage Directive |
International Safety of ITE |
CB Report & Certificate per IEC 60950-1:2005 2nd Ed. + National Differences AS/NZX 60950-1 (Australia /New Zealand) |
Operating conditions | Temperature: 0°C to 50°C (32°F to 122°F) for non-PoE
models Temperature: 0°C to 45°C (32°F to 113°F) for PoE models Storage and transportation temperature: -40°C to 70°C (-40°F to 158°F) Humidity: 5% to 95% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) |