X450-G2-24t-GE4 X450-G2-24t-10GE4 X450-G2-48t-GE4 X450-G2-48t-10GE4 X450-G2-24p-GE4 X450-G2-24p-10GE4 X450-G2-48p-GE4 X450-G2-48p-10GE4 |
Height: 1.73 inches (4.4 cm) Width: 17.4 inches (44.1 cm) Depth: 19.2 inches (43.2 cm) |
X450-G2-24t-GE4 X450-G2-24t-10GE4 |
13.71 lb (6.22 kg) |
X450-G2-48t-GE4 X450-G2-48t-10GE4 |
14.22 lb (6.45 kg) |
X450-G2-24p-GE4 X450-G2-24p-10GE4 |
13.93 lb (6.32 kg) |
X450-G2-48p-GE4 X450-G2-48p-10GE4 |
14.51 lb (6.58 kg) |
X450-G2-24t-GE4 X450-G2-24t-10GE4 X450-G2-48t-GE4 X450-G2-48t-10GE4 X450-G2-24p-GE4 X450-G2-24p-10GE4 X450-G2-48p-GE4 X450-G2-48p-10GE4 |
Height: 6.70 inches (17.02 cm) Width: 22.85 inches (58.04 cm) Depth: 24.03 inches (60.96 cm) |
X450-G2-24t-GE4 X450-G2-24t-10GE4 |
20.72 lb (9.50 kg) |
X450-G2-48t-GE4 X450-G2-48t-10GE4 |
21.23 lb (9.74 kg) |
X450-G2-24p-GE4 X450-G2-24p-10GE4 |
20.94 lb (9.61 kg) |
X450-G2-48p-GE4 X450-G2-48p-10GE4 |
21.52 lb (9.87 kg) |
Switch Model | Bystander Sound Pressure | Declared Sound Power |
---|---|---|
X450-G2-24t-GE4 X450-G2-24t-10GE4 Fixed AC or DC power supply with front-to-back (FB) airflow |
49.8 dB(A), 0°C to 39°C 64.9 dB(A), 50°C |
6.1 bels, 0°C to 39°C 7.6 bels, 50°C |
X450-G2-48t-GE4 X450-G2-48t-10GE4 Fixed AC or DC power supply with front-to-back (FB) airflow |
49.9 dB(A), 0°C to 39°C 64.8 dB(A), 50°C |
6.1 bels, 0°C to 39°C 7.6 bels, 50°C |
X450-G2-24p-GE4 X450-G2-24p-10GE4 Dual 715 W AC or DC power supply with front-to-back (FB) airflow |
51.1 dB(A), 0°C to 39°C 65.5 dB(A), 50°C |
6.2 bels, 0°C to 39°C 7.7 bels, 50°C |
X450-G2-24p-GE4 X450-G2-24p-10GE4 Dual 715 W AC or DC power supply with front-to-back (FB) airflow with applied PoE load |
50.1 dB(A), 0°C to 39°C 64.5 dB(A), 50°C |
6.1 bels, 0°C to 39°C 7.6 bels, 50°C |
X450-G2-48p-GE4 X450-G2-48p-10GE4 Dual 1100 W AC or DC power supply with front-to-back (FB) airflow |
50.8 dB(A), 0°C to 39°C 65.4 dB(A), 50°C |
6.2 bels, 0°C to 39°C 7.6 bels, 50°C |
X450-G2-48p-GE4 X450-G2-48p-10GE4 Dual 1100 W AC or DC power supply with front-to-back (FB) airflow with applied PoE load |
56.5 dB(A), 0°C to 39°C 66.8 dB(A), 50°C |
6.8 bels, 0°C to 39°C 7.8 bels, 50°C |
Note
Acoustic noise levels represent noise emitted by the switch at room ambient temperatures. Values are based on a fully configured system consisting of two PSUs operating under full load. Normal operating temperature range: 0°C to 50°C.Fan Speed | Fan Module RPM (typical) | Power | ||
---|---|---|---|---|
Inlet Fan | Outlet Fan | Maximum | Typical | |
Full | 14,000 (±15%) | 7,000 (±15%) | 36 W | 30.6 |
Low | 6,400 (±15%) | 2,900 (±15%) | 3.96 W (typical) |
Switch Model | Power Supply |
---|---|
Fixed power supply with front-to-back airflow | |
X450-G2-24t-GE4 X450-G2-24t-10GE4 |
100-240 V, 50/60 Hz, 1.0 A |
X450-G2-48t-GE4 X450-G2-48t-10GE4 |
100-240 V, 50/60 Hz, 1.0 A |
Modular power supply with front-to-back airflow | |
X450-G2-24p-GE4 X450-G2-24p-10GE4 |
1100 W AC PS FB (front-to-back) Part # 10941, Model: PSSF112101A 100-127V/200-240 V, 50/60 Hz, 10.0 A/5.0 A max per PS |
X450-G2-24p-GE4 X450-G2-24p-10GE4 |
715 W AC PS FB (front-to-back) Part # 10951, Model: PSSF711101A 100-127V/200-240 V, 50/60 Hz, 7.0 A/3.5 A max per PS |
X450-G2-48p-GE4 X450-G2-48p-10GE4 |
1100 W AC PS FB (front-to-back) Part # 10941, Model: PSSF112101A 100-127V/200-240 V, 50/60 Hz, 12.0 A/6.0 A max per PS |
X450-G2-48p-GE4 X450-G2-48p-10GE4 |
715 W AC PS FB (front-to-back) Part # 10951, Model: PSSF711101A 100-127V/200-240 V, 50/60 Hz, 8.0 A/4.0 A max per PS |
Switch Model | Minimum Heat Dissipation | Minimum Power Consumption | Maximum Heat Dissipation | Maximum Power Consumption |
---|---|---|---|---|
X450-G2-24t-GE4 X450-G2-24t-10GE4 |
149.4 BTU/hr | 43.8 W | 244.6 BTU/hr | 71.1 W |
X450-G2-48t-GE4 X450-G2-48t-10GE4 |
178.1 BTU/hr | 52.2 W | 290.0 BTU/hr | 85.0 W |
X450-G2-24p-GE4 (@ 720 W PoE) |
214.3 BTU/hr | 62.8 W | 604.7 BTU/hr | 127.2 W |
X450-G2-24p-10GE4 (@ 720 W PoE) |
214.3 BTU/hr | 62.8 W | 604.7 BTU/hr | 847.2 W |
X450-G2-48p-GE4 (@ 1440 W PoE) |
238.8 BTU/hr | 70.0 W | 778 BTU/hr | 228 W |
X450-G2-48p-10GE4 (@ 1440 W PoE) |
238.8 BTU/hr | 70.0 W | 778 BTU/hr | 1668 W |
Switch Model | 1 PSU of 715 W | 1 PSU of 1100 W | 2 PSUs of 715 W | 1 PSU of 715 W & 1 PSU of 1100 W | 2 PSUs of 1100 W |
---|---|---|---|---|---|
X450-G2-24p-GE4 | 500 W | 720 W | 720 W | 720 W | 720 W |
X450-G2-24p-10GE4 | 500 W | 720 W | 720 W | 720 W | 720 W |
X450-G2-48p-GE4 | 500 W | 850 W | 1031 W | 1350 W | 1440 W |
X450-G2-48p-10GE4 | 500 W | 850 W | 1031 W | 1350 W | 1440 W |
X450-G2-24p-GE4 | 16 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
X450-G2-24p-10GE4 | 16 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
24 ports @ 30
W 24 ports @ 15.4 W |
X450-G2-48p-GE4 | 16 ports @ 30
W 32 ports @ 15.4 W |
28 ports @ 30
W 48 ports @ 15.4 W |
34 ports @ 30
W 48 ports @ 15.4 W |
45 ports @ 30
W 48 ports @ 15.4 W |
48 ports @ 30
W 48 ports @ 15.4 W |
X450-G2-48p-10GE4 | 16 ports @ 30
W 32 ports @ 15.4 W |
28 ports @ 30
W 48 ports @ 15.4 W |
34 ports @ 30
W 48 ports @ 15.4 W |
45 ports @ 30
W 48 ports @ 15.4 W |
48 ports @ 30
W 48 ports @ 15.4 W |
CPU/Memory |
---|
1 GHz 64-bit CPU |
1 GB DDR3 ECC DRAM |
4 GB eMMC Flash Memory |
4 MB packet buffer per chip |
North American Safety of ITE |
UL 60950-1 1st Ed., Listed Device (US) CSA 22.2 #60950-1-07 2nd Ed.(Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) |
European Safety of ITE |
EN 60950-1:2006 2nd Ed. TUV-R GS EN 60825-1:2007 (Lasers Safety) 2006/95/EC Low Voltage Directive |
International Safety of ITE |
CB Report & Certificate per IEC 60950-1:2005 2nd Ed., + National Differences AS/NZX 60950-1 (Australia /New Zealand) |
North America EMC for ITE |
FCC CFR 47 part 15 Class A (USA) ICES-003 Class A (Canada) |
European EMC standards |
EN 55022:2006+A1:2007 Class A EN 55024:1998+A1:2001+A2:2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11 EN 61000-3-2: 2006+A2:2009 (Harmonics) EN 61000-3-3:2008 (Flicker) ETSI EN 300 386: v1.4.1 (2008-04) (EMC Telecommunications) 2004/108/EC EMC Directive |
International EMC certifications |
CISPR 22: 2008 (Ed 6.0), Class A (International Emissions) EN 55024:1998+A1:2001+A2:2003 Class A (International Immunity) IEC/EN 61000-4-2:2008 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A IEC/EN 61000-4-3:2008 Radiated Immunity 10V/m, Criteria IEC/EN 61000-4-4:2004 Transient Burst, 1 kV, Criteria A IEC/EN 61000-4-5:2005 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A IEC/EN 61000-4-6:2008 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods, Criteria C |
Country-specific |
VCCI Class A (Japan Emissions) BSMI (Taiwan Emissions) ACMA (C-Tick) (Australia Emissions) CCC Mark (China) KCC Mark, EMC Approval (Korea) |
EN/ETSI 300 386:2008 (EMC Telecommunications) EN/ETSI 300 019 (Environmental for Telecommunications) MEF9 and MEF14 certified for EPL, EVPL, and ELAN |
IEEE 802.3ab 1000BASE-T IEEE 802.3z 1000BASE-X IEEE 802.3ae 10GBASE-X IEEE 802.3at PoE Plus IEEE 802.3az (EEE) |
Environmental standards |
EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5G |
Operating conditions |
Temperature range: 0°C to 50°C (32°F to 122°F) Humidity: 10% to 95% relative humidity, non-condensing Altitude: 0 to 5,000 meters (16,404 feet) – PoE switches Altitude: 0 to 2,000 meters (6,562 feet) – non-PoE switches Operational shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks Operational random vibration: 3 to 500 Hz at 1.5 G rms |
Storage & transportation conditions (packaged) |
Transportation temperature: -40°C to 70°C (-40°F to 158°F) Storage and transportation humidity: 10% to 95% relative humidity, non-condensing Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged sine vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2 G Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz 14 drops minimum on sides and corners at 42 inches (<15 kg box) |