ExtremeSwitching X620 Series Switches Technical Specifications

The ExtremeSwitching X620 series includes the following switches:

Physical Dimensions

Table 1. Physical Dimensions
X620-8t-2x

X620-10x

Height: 1.73 inches (4.4 cm)

Width: 12.01 inches (30.5 cm)

Depth: 10.28 inches (26.1 cm)

X620-16t

X620-16x

Height: 1.73 inches (4.4 cm)

Width: 17.38 inches (44.1 cm)

Depth: 16.94 inches (43.0 cm)

Weight

Table 2. Weight
X620-8t-2x 6.37 lb (2.92 kg)
X620-10x 6.04 lb (2.77 kg)
X620-16t 12.04 lb (5.52 kg)
X620-16x 11.11 lb (5.10 kg)

Packaged Dimensions

Table 3. Packaged Dimensions
X620-8t-2x

X620-10x

Height: 6.23 inches (15.8 cm)

Width: 15.17 inches (38.5 cm)

Depth: 22.46 inches (57.0 cm)

X620-16t

X620-16x

Height: 6.66 inches (16.9 cm)

Width: 21.63 inches (54.9 cm)

Depth: 22.93 inches (58.2 cm)

Packaged Weight

Table 4. Packaged Weight
X620-8t-2x 9.41 lb (4.32 kg)
X620-10x 9.04 lb (4.15 kg)
X620-16t 17.79 lb (8.16 kg)
X620-16x 16.91 lb (7.76 kg)

Fan Speed

Table 5. Fan Speed
X620-8t-2x Continuously variable speed as needed
X620-10x Continuously variable speed as needed
X620-16t Continuously variable speed as needed
X620-16x Continuously variable speed as needed

Acoustic Sound

Table 6. Acoustic Sound
Bystander Sound Pressure Declared Sound Power
X620-8t-2x

(side-side airflow)

35.6 db(A) up to 25°C

38.8 db(A) up to 30°C

65.4 db(A) at 50°C (max)

4.8 bels up to 25°C

5.2 bels up to 30°C

7.9 bels at 50°C (max)

X620-10x

(side-side airflow)

28.2 db(A) up to 35°C

66.3 db(A) at 50°C (max)

3.8 bels up to 35°C

7.9 bels at 50°C (max)

X620-16t

(front-back airflow)

47.2 db(A) up to 35°C

65.6 db(A) at 50°C (max)

6.2 bels up to 35°C

8.0 bels at 50°C (max)

X620-16t

(back-front airflow)

46.9 db(A) up to 30°C

65.2 db(A) at 50°C (max)

6.2 bels up to 30°C

8.1 bels at 50°C (max)

X620-16x

(front-back airflow)

47.0 db(A) up to 40°C

65.7 db(A) at 50°C (max)

6.1 bels up to 40°C

8.0 bels at 50°C (max)

X620-16x

(back-front airflow)

46.9 db(A) up to 40°C

64.8 db(A) at 50°C (max)

6.1 bels up to 40°C

8.0 bels at 50°C (max)

Power Specifications

Table 7. Power Specifications
Minimum1 Heat Dissipation (BTU/hr) Minimum1 Power Consumption (Watts) Maximum1 Heat Dissipation (BTU/hr) Maximum1 Power Consumption (Watts)
X620-8t-2x 74 22 177 52
X620-10x 60 18 123 36
X620-16t 175 51 347 102
X620-16t (DC) 148 43 326 96
X620-16x 111 33 214 63
X620-16x (DC) 80 23 180 53

Power Supplies

Table 8. Power Supplies
Power Supplies
X620-8t-2x

Integrated 100 W AC PSU

RPS connector for external redundant PSU

Side-to-side airflow

X620-10x
X620-16t

Modular 300 W power supply (up to two PSU)

AC and DC power options

Mix AC and DC configuration

Front-to-back or back-to-front airflow options

X620-16x

CPU, Memory

Table 9. CPU, Memory
CPU/Memory
1 GHz CPU
1 GB DDR3 ECC memory
4 GB eMMC Flash memory

Environmental Data

Table 10. Environmental Data

Environmental specifications

EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage

EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation

EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational

EN/ETSI 300 753 (1997-10) - Acoustic Noise

ASTM D3580 Random Vibration Unpackaged 1.5 G

Operating conditions

Temp: 0°C to 50°C (32°F to 122°F) – all models

Humidity: 10% to 95% relative humidity, non-condensing

Altitude: 0 to 3,000 meters (9,842 feet) – All switch models

Shock (half sine): 30 m/s2 (3 G), 11 ms, 6 shocks

Random vibration: 3 to 500 Hz at 1.5 G rms

Packaging and storage specifications

Temp: -40°C to 70°C (-40°F to 158°F)

Humidity: 10% to 95% relative humidity, non-condensing

Packaged Shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks

Packaged Vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2 G

Packaged Random Vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz

Packaged Drop Height: 14 drops minimum on sides and corners at 42 inches (<15 kg box)

Scaling and Performance

For scaling and performance specifications, refer to the product data sheet.

Safety Standards

Table 11. Safety Standards

North American ITE

UL 60950-1 2nd Ed., Listed Device (US)

CSA 22.2 #60950-1-03 2nd Ed.(Canada)

Complies with FCC 21CFR 1040.10 (US Laser Safety)

CDRH Letter of Approval (US FDA Approval)

European ITE

EN 60950-1:2007 2nd Ed.

EN 60825-1+A2:2001 (Lasers Safety)

2014/35/EU Low Voltage Directive

International ITE

CB Report & Certificate per IEC 60950-1 2nd Ed. + National Differences

AS/NZX 60950-1 (Australia /New Zealand)

EMI/EMC Standards

Table 12. EMI/EMC Standards

North America EMC for ITE

FCC CFR 47 part 15 Class A (USA)

ICES-003 Class A (Canada)

European EMC standards

EN 55022:2006+A1:2007 Class A

EN 55024:A2-2003 Class A includes IEC 61000-4-2, 3, 4, 5, 6, 11

EN 61000-3-2,8-2006 (Harmonics)

EN 61000-3-3:2008 (Flicker)

ETSI EN 300 386 v1.4.1, 2008-04 (EMC Telecommunications)

2014/30/EUC EMC Directive

International EMC certifications

CISPR 22: 2006 Ed 5.2, Class A (International Emissions)

CISPR 24:A2:2003 Class A (International Immunity)

IEC 61000-4-2:2008/EN 61000-4-2:2009 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A

IEC 61000-4-3:2008/EN 61000-4-3:2006+A1:2008 Radiated Immunity 10V/m, Criteria A

IEC 61000-4-4:2004 am1 ed.2./EN 61000-4-4:2004/A1:2010 Transient Burst, 1 kV, Criteria A

IEC 61000-4-5:2005 /EN 61000-4-5:2006 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A

IEC 61000-4-6:2008/EN 61000-4-6:2009 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A

IEC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods, Criteria C

Country-specific

VCCI Class A (Japan Emissions)

ACMA RCM (Australia Emissions)

CCC Mark

KCC Mark, EMC Approval (Korea)

Telecom Standards

Table 13. Telecom Standards
CE 2.0 compliant

IEEE 802.3 Media Access Standards

Table 14. IEEE 802.3 Media Access Standards

IEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-X

IEEE 802.3ae 10GBASE-X

IEEE 802.3at PoE-Plus

IEEE 802.3az (EEE)

IEEE 802.3u, 100BASE-FX


1 Minimum is defined as idle, with no ports linked. Maximum is defined as fans high, all ports 100% traffic.