The ExtremeSwitching X590 series includes the following switches:
X590-24t-1q-2c X590-24x-1q-2c |
Height: 1.71 in (4.35 cm) Width: 19.19 in (48.7 cm) Length: 17.38 in (44.1 cm) |
X590-24t-1q-2c | 14.99 lb (6.8 kg) |
X590-24x-1q-2c | 14.55 lb (6.6 kg) |
X590-24t-1q-2c X590-24x-1q-2c |
Height: 6.07 in (15.4 cm) Width: 21.35 in (54.2 cm) Length: 23.17 in (58.8 cm) |
X590-24t-1q-2c | 20.5 lb (9.3 kg) |
X590-24x-1q-2c | 19.5 lb (8.85 kg) |
Switch Model | Bystander Sound Pressure (at 25°C) | Declared Sound Power (at 25°C) |
---|---|---|
X590-24t-1q-2c (part no. 16791) FB airflow |
54.7 db(A) up to 25°C 61.9 db(A) up to 35°C 79.4 db(A) at 45°C (max) |
6.8 bels up to 25°C 7.6 bels up to 35°C 9.4 bels at 45°C (max) |
X590-24t-1q-2c (part no. 16791) BF airflow |
55.5 db(A) up to 25°C 62.6 db(A) up to 35°C 79.7 db(A) at 45°C (max) |
6.8 bels up to 25°C 7.5 bels up to 35°C 9.2 bels at 45°C (max) |
X590-24x-1q-2c (part no. 16790) FB airflow |
55.6 db(A) up to 30°C 57.8 db(A) up to 40°C 79.8 db(A) at 45°C (max) |
6.9 bels up to 30°C 7.1 bels up to 40°C 9.5 bels at 45°C (max) |
X590-24x-1q-2c (part no. 16790) BF airflow |
55.8 db(A) up to 30°C 57.9 db(A) up to 40°C 79.1 db(A) at 45°C (max) |
6.9 bels up to 30°C 7.1 bels up to 40°C 9.4 bels at 45°C (max) |
X590-24t-1q-2c (part #
16791) X590-24x-1q-2c (part # 16790) |
770
W AC power supply: Part # 10960 770 W AC PS FB (front-back) Part # 10961 770 W AC PS FB (back-front) AC Input: 100-240 VAC, 50/60 Hz PSU Input Socket: IEC 320 C14 Power cord input plug: IEC 320 C13 |
1100 W DC power supply: Part # 10962 1100 W DC PS FB (front-back) Part # 10963 1100 W DC PS FB (back-front) DC Input: -48 VDC |
Switch Model | |
---|---|
X590-24t-1q-2c X590-24x-1q-2c |
AC Input: 100-127 VAC, 2.5 A max. per PSU, 50/60 Hz AC Input: 200-240 VAC, 1.25 A max. per PSU, 50/60 Hz DC Input: -48 to -60 VDC, 5.0 A max. per PSU |
Minimum1 Heat Dissipation (1 PSU) | Minimum1 Power Consumption | Maximum1 Heat Dissipation (2 PSUs) | Maximum1 Power Consumption | |
---|---|---|---|---|
X590-24t-1q-2c-AC |
310.97 BTU/hr |
91.14 W |
792.27 BTU/hr |
232.20 W |
X590-24t-1q-2c-DC |
332.63 BTU/hr |
97.49 W |
833.62 BTU/hr |
244.32 W |
X590-24x-1q-2c-AC |
278.42 BTU/hr |
81.60 W |
743.82 BTU/hr |
218.00 W |
X590-24x-1q-2c-DC |
286.61 BTU/hr |
84.00 W |
786.12 BTU/hr |
230.40 W |
CPU/Memory |
---|
1GHz 64-bit CPU |
2GB DDR3 ECC SDRA memory |
4GB eMMC Flash Memory |
12 MB buffer, per chip |
North American Safety of ITE |
UL 60950-1 2nd Ed., A2:2014, Listed Device (US) CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada) Complies with FCC 21CFR 1040.10 (US Laser Safety) CDRH Letter of Approval (US FDA Approval) |
European Safety of ITE |
EN 60950-1:2006+A11:2009+A1:2010+A12:2011+A2:2013 2nd Ed. EN 60825-1:2007 IEC 60825-1:2007 Class 1 (Lasers Safety) 2014/35/EU Low Voltage Directive |
International Safety of ITE |
CB Report & Certificate per IEC 60950-1:2005+A1:2009+A2:2013 + National Differences AS/NZX 60950-1 (Australia /New Zealand) |
North America EMC for ITE |
FCC 47 CFR part 15 Class A (USA) ICES-003 Class A (Canada) |
European EMC standards |
EN 55032:2015 Class A EN 55024:2010 EN 61000-3-2,2014 (Harmonics) EN 61000-3-3,2013 (Flicker) 2014/30/EU EMC Directive EN 300 386: v1.6.1 (EMC Telecommunications) |
International EMC certifications |
CISPR 32: 2015, Class A (International Emissions) CISPR 24: 2010, Class A (International Immunity) AS/NZS CISPR32:2015 IEC 61000-4-2:2008/EN 61000-4-2:2009 Electrostatic Discharge, 8kV Contact, 15 kV Air, Criteria A IEC 61000-4-3:2010/EN 61000-4-3:2006+A1:2008+A2:2010 Radiated Immunity 10V/m, Criteria A IEC 61000-4-4:2012/EN 61000-4-4:2012 Transient Burst, 1 kV, Criteria A IEC 61000-4-5:2014/EN 61000-4-5:2014 Surge, 2 kV L-L, 2 kV L-G, Level 3, Criteria A IEC 61000-4-6:2013/EN 61000-4-6:2014 Conducted Immunity, 0.15-80 MHz, 10V/m unmod. RMS, Criteria A IEC/EN 61000-4-11:2004 Power Dips & Interruptions, >30%, 25 periods, Criteria C |
Country-specific |
ACMA RCM (Australia Emissions) VCCI Class A (Japan Emissions) CCC mark (China) KCC mark, EMC Approval (Korea) |
CE 2.0 Compliant |
IEEE 802.3ba /802.3bm 40GBASE-X and 100GBASE-X IEEE 802.3ae 10GBASE-X IEEE 802.3 10GBASE-T (up to 100 m using Cat 6a cabling or better) 25Gb and 50Gb Ethernet implemented per 25G/50G Ethernet Consortium specification and IEEE 802.3 standard |
Environmental standards |
EN/ETSI 300 019-2-1 v2.1.2 - Class 1.2 Storage EN/ETSI 300 019-2-2 v2.1.2 - Class 2.3 Transportation EN/ETSI 300 019-2-3 v2.1.2 - Class 3.1e Operational EN/ETSI 300 753 (1997-10) - Acoustic Noise ASTM D3580 Random Vibration Unpackaged 1.5G |
Environmental compliance |
EU RoHS - 2011/65/EU EU WEEE - 2012/19/EU China RoHS - SJ/T 11363-2006 Taiwan RoHS - CNS 15663 (2013.7) |
Operating conditions |
Temperature range: 0°C to 45°C (32°F to 113°F) Humidity: 5% to 95% relative humidity, non-condensing Altitude: 0 to 3,000 meters (9,850 feet) Operational shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks Operational random vibration: 3 to 500 Hz at 1.5 G rms |
Storage & transportation conditions (packaged) |
Transportation temperature: -40°C to 70°C (-40°F to 158°F) Storage and transportation humidity: 10% to 95% relative humidity, non-condensing Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks Packaged vibration: 5 to 62 Hz at velocity 5 mm/s, 62 to 500 Hz at 0.2 G Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct. from 20 to 200 Hz 14 drops minimum on sides and corners at 42 in (<15 kg box) |