To define ADSP server credentials for WiNG controller or service platform data exchanges:
The RF Domain's sensor appliance configuration screen displays.
Server Id | Assign a numerical ID for up to three ADSP server resources. The server with the lowest defined ID is the first reached by the controller or service platform. The default ID is 1. |
IP Address/Hostname | Provide the numerical (non DNS) IP address or hostname of each server used as a ADSP sensor server by RF Domain member devices. A hostname cannot exceed 64 characters or contain an underscore. |
Port | Specify the port of each ADSP sensor server utilized by RF member devices. The default port is 443. |
Sensor Policy | Use the Sensor Policy drop-down menu to select a Sensor policy. If no Sensor policy
exists, use the Create icon to create a new Sensor policy.
Or, use the Edit icon to edit an existing Sensor policy
if required. Note: If a
dedicated sensor is utilized with WIPS for rogue
detection, any sensor policy selected from the Sensor
Policy drop-down menu is discarded and not utilized by
the sensor. To avoid this situation, use ADSP channel
settings exclusively to configure the sensor and not the
WiNG
interface.
|
Server Id Policy | Use the spinner control to assign
a numerical ID for the ExtremeLocation server resource. Note: As of now only one server is
supported.
|
IP Address/Hostname | Provide the hostname of the
ExtremeLocation server used by RF Domain member devices. A
hostname cannot exceed 64 characters or contain an
underscore. Note: Enter the
ExtremeLocation server‘s hostname and not the IP
address, as the IP address is likely to periodically
change in order to balance load across multiple Location
servers.
|