Removing an RPS-150XT Redundant Power Supply
    
    
        
            To remove an installed RPS-150XT that is attached to a switch,
                follow these steps.
            
Caution   
 Observe all ESD precautions when handling
          sensitive electronic equipment.
 
            
Note   
The switch should not be powered on
                during installation or removal of the power supply. This is not a hot-swap
                procedure. Follow the steps in the order specified.
 
         
        
            - Unplug the AC power cord from the AC power source first
            and then from the power supply.
 
            - Disconnect the RPS
            cable from the Redundant Power Supply connector at the rear of the power supply.
 
            - Disconnect the RPS cable from the Redundant Power Supply
            connector on the switch.
 
            - If the power supply is installed in a rack, remove it
            from the rack:
- Holding the power supply securely, remove the
                captive screws that secure it to the STK-RPS-1005CH3 shelf.
 
- Carefully slide the power supply out of the
                shelf.
 
 
            - 
                If you want to replace the power supply with
                    another one, follow the instructions in Installing an RPS-150XT Redundant Power Supply.