ExtremeSwitching X695 Series Switch Technical Specifications

The ExtremeSwitching X695-48Y-8C switch includes six unpopulated fan slots and two unpopulated power supply slots.

Click to expand in new window

X695 Unpackaged Dimensions

X695-48Y-8C switch Height: 4.34 cm (1.71 in)

Width: 43.96 cm (17.31 in)

Length: 53.95 cm (21.24 in)

Fan unit, front-to-back or back-to-front

Height: 4.0 cm (1.57 in)

Width: 4.0 cm (1.57 in)

Length: 13.4 cm (5.28 in)

Four-post rack mount kit (included with switch)

Height: 2.1 cm (0.83 in)

Width: 4.4 cm (17.3 in)

Length: 63.0 cm - 90.0 cm (24.80 in - 35.43 in)

Two-post rack mount kit (ordered separately)

Height: 4.2 cm (1.65 in)

Width: 2.4 cm (0.93 in)

Length: 12.5 cm (4.92 in)

Click to expand in new window

X695 Unpackaged Weight

X695-48Y-8C switch with no PSUs

7.39 kg (16.29 lb)

Fan unit, front-to-back or back-to-front

0.14 kg (0.31 lb)

Four-post rack mount kit (included with switch)

2.65 kg (5.84 lb)

Two-post rack mount kit (ordered separately)

0.45 kg (0.99 lb)

Click to expand in new window

X695 Packaged Dimensions

X695-48Y-8C switch Height: 18.5 cm (7.28 in)

Width: 60.0 cm (23.62 in)

Length: 88.0 cm (34.65 in)

Fan unit, front-to-back or back-to-front

Height: 24.0 cm (9.45 in)

Width: 20.6 cm (8.11 in)

Length: 22.1 cm (8.70 in)

Four-post rack mount kit (included with switch)

Height: 7.0 cm (2.76 in)

Width: 11.0 cm (4.33 in)

Length: 84.0 cm (33.07 in)

Two-post rack mount kit (ordered separately)

Height: 24.0 cm (9.45 in)

Width: 20.6 cm (8.11 in)

Length: 22.1 cm (8.70 in)

Click to expand in new window

X695 Packaged Weight

X695-48Y-8C switch with no PSUs

14.59 kg (32.17 lb)

Fan unit, front-to-back or back-to-front

1.82 kg (4.01 lb)

Four-post rack mount kit (included with switch)

2.71 kg (5.97 lb)

Two-post rack mount kit (ordered separately)

3.20 kg (7.05 lb)

Fan and Acoustic Noise

Click to expand in new window

Fan and Acoustic Noise

Switch Model Bystander Sound Pressure (at 25°C) Declared Sound Power (at 25°C)
X695-48Y-8C-F

(FB airflow)

52.2 db(A) 6.8 bels
X695-48Y-8C-R

(BF airflow)

50.5 db(A) 6.7 bels

Fan Tray and Speed Variation

Fan speeds are adjusted based on calculations of the temperatures on all sensors. Due to one fan being located behind the other, air pushed from one fan may cause the other fan in the module to run at a higher speed. One fan can run at medium speed while the other can spin at high speed if one is close to the temperature boundary.

Click to expand in new window

Fan Tray Speed Variation

Description Operation Status Operation Speed Airflow Direction
Tray 1 Fan 1 up high speed unknown*
Tray 1 Fan 2 up medium speed unknown*
Tray 2 Fan 1 up high speed unknown*
Tray 2 Fan 2 up medium speed unknown*
Tray 3 Fan 1 up high speed unknown*
Tray 3 Fan 2 up medium speed unknown*
Tray 4 Fan 1 up high speed unknown*
Tray 4 Fan 2 up medium speed unknown*
Tray 5 Fan 1 up high speed unknown*
Tray 5 Fan 2 up medium speed unknown*
Tray 6 Fan 1 up high speed unknown*
Tray 6 Fan 2 up medium speed unknown*

*The color of the tab on the fan tray indicates the airflow direction:

  • Red = Front-to-Back
  • Blue = Back-to-Front

Power Options

Click to expand in new window

X695 Power Options

X695-48Y-8C 750 W AC power supply:

Part # XN-ACPWR-750W-F (front-to-back)

Part # XN-ACPWR-750W-R (back-to-front)

AC Input: 100-120/200-240 VAC, 50/60 Hz

3.5/1.8 A max. for each PSU

PSU Input Socket: IEC 320 C14

Power cord input plug: IEC 320 C13

750 W DC power supply:

Part # XN-DCPWR-750W-F (front-to-back)

Part # XN-DCPWR-750W-R (back-to-front)

DC Input: -54 VDC, 7.0 A max. for each PSU

Power Consumption

Click to expand in new window

X695 Power Consumption

Switch Model Minimum Heat Dissipation (BTU/hr) Minimum Power Consumption (W) Maximum Heat Dissipation (BTU/hr) Maximum Power Consumption (W)

X695-48Y-8C

553 167 1600 469

Mean Time Between Failures (MTBF)

Click to expand in new window

X695-48Y-8C MTBF

Switch Mean Time Between Failures
X695-48Y-8C-AC-F 389719 hrs @ 25°C
X695-48Y-8C-AC-R 450269 hrs @ 25°C

CPU, Memory

Click to expand in new window

CPU, Memory

2.2 GHz 64-bit CPU
16 Gb memory, 128 Gb SSD
4GB eMMC Flash Memory
32 MB buffer, per chip

Standards

Click to expand in new window

Safety Standards

North American Safety of ITE

UL 62368-1 2nd Ed., 2014-12-01, Listed Device (US)

UL 60950-1 2nd Ed., 2014-10-14, Listed Device (US)

CAN/CSA 22.2 #62368-1-14 2nd Ed., Canada

CAN/CSA 22.2 #60950-1-07 2nd Ed., Canada 2014-10

Complies with FCC 21 CFR Chapter 1, Sub-chapter J in accordance with FDA & CDRH requirements (US Laser Safety)

CDRH Letter of Approval (US FDA Approval)

European Safety of ITE

EN 62368-1

EN 60950

2014/35/EU Low Voltage Directive

International Safety of ITE

CNS 14336-1

AS/NZX 60950-1 (Australia /New Zealand)

GB4943.1

IEC/EN 60825, IEC/EN 60825-2 (Lasers Safety)

IEC 62368-1

IEC 60950-1

Click to expand in new window

EMI/EMC Standards

North America EMC for ITE

  • FCC 47 CFR part 15 subpart B Class A (USA)
  • ICES-003 (Canada)

European EMC standards

  • EN 300 386 V2.1.1(2016-07) Class A
  • EN 55032:2015/AC:2016-07 Class A
  • EN 55024:2010/A1:2015
  • EN 55011:2009+A1:2010 (Group 1, Class A)
  • EN 61000-6-2:2005+AC:2005
  • EN 61000-6-4:2007+A1:2011
  • EN 61000-3-2:2014 Class A
  • EN 61000-3-3:2013
  • EN 61000-4-2:2009
  • EN 61000-4-3:2006+A1:2008+A2:2010
  • EN 61000-4-4:2012
  • EN 61000-4-5:2014
  • EN 61000-4-6:2014/AC:2015
  • EN 61000-4-8:2010
  • EN 61000-4-11:2004/A1:2017

International EMC certifications

  • IEC 61000-6-2:2016 ED 3.0
  • IEC 61000-6-4:2018 ED 3.0
  • IEC 61000-4-2:2008 ED 2.0
  • IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 ED 3.2
  • IEC 61000-4-4:2012 ED 3.0
  • IEC 61000-4-5:2014+AMD1:2017+ ED 3.1
  • IEC 61000-4-6:2013+ ED 4.0
  • IEC 61000-4-8:2009+ ED 2.0
  • IEC 61000-4-11:2004+AMD1:2017+ ED 2.1
  • CISPER 32:2015 ED 2.0 Class A
  • CISPER 24:2010+AMD1:2015 Class A
  • CISPER 11:2009 ED 5.0 Group 1, Class A
  • AS/NZS CISPER 32:2015 Class A
  • GB/T9254-2008 Class A
  • ANSI C63.4:2014

Country-specific

  • RCM (Australia)
  • VCCI Class A (Japan)
  • MSIP KCC (Korea)
  • BSMI (Taiwan)
  • ANATEL (Brazil)
  • CCC mark (China)
  • SABS & NRCS (South Africa)
  • UL, FCC (North America)
  • EAC mark (Custom Union)
Click to expand in new window

Telecom Standards

EN/ETSI 300 386:2008 (EMC Telecommunications)

EN/ETSI 300 019 (Environmental for Telecommunications)

MEF9 and MEF14 certified for EPL, EVPL, and ELAN

Click to expand in new window

IEEE 802.3 Media Access Standards

IEEE 802.3ab 1000BASE-T

IEEE 802.3z 1000BASE-X

IEEE 802.3ae 10GBASE-X

IEEE 802.3ba 40GBASE-X

Environmental Data

Click to expand in new window

Environmental Data

Environmental standards

EN/ETSI 300 019-2-1 v2.1.2 (2000 - 2009) - Class 1.2 Storage

EN/ETSI 300 019-2-2 v2.1.2 (1999 - 09) - Class 2.3 Transportation

EN/ETSI 300 019-2-3 v2.1.2 (2003 - 04) - Class 3.1e Operational

EN/ETSI 300 753 (1997-10) - Acoustic Noise

ASTM D3580 Random Vibration Unpackaged 1.5G

Temperature range

  • Front-to-back airflow: 0°C to 50°C (32°F to 122°F) up to 1800m (6000 ft)
  • Front-to-back airflow: 0°C to 45°C (32°F to 113°F) above 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 45°C (32°F to 113°F) up to 1800m (6000 ft)
  • Back-to-front airflow: 0°C to 40°C (32°F to 104°F) above 1800m (6000 ft)

Other operating conditions

Humidity: 5% to 95% relative humidity, non-condensing

Altitude: 0 to 3,000 meters (9,850 feet)

Operational shock (half sine): 30 m/s2 (3 G), 11 ms, 60 shocks

Operational random vibration: 3 to 500 Hz at 1.5 G rms

Storage & transportation conditions (packaged)

Transportation temperature: -40°C to 70°C (-40°F to 158°F)

Humidity: 5% to 95% relative humidity, non-condensing

Packaged shock (half sine): 180 m/s2 (18 G), 6 ms, 600 shocks

Packaged sine vibration: 5 to 62 Hz at velocity 5 mm/s,

62 to 500 Hz at 0.2 G

Packaged random vibration: 5 to 20 Hz at 1.0 ASD w/–3 dB/oct.

from 20 to 200 Hz

14 drops minimum on sides and corners at 42 in (<15 kg box)