V400 Virtual Port Extender Technical Specifications

The following V400 Virtual Port Extender models are available:

  • V400-24t-10GE2 (part no. 18101)
  • V400-24p-10GE2 (part no. 18102)
  • V400-48t-10GE4 (part no. 18103)
  • V400-48p-10GE4 (part no. 18104)
Click to expand in new window

V400 Unpackaged Dimensions

V400-24t-10GE2 Height: 1.70 in (4.32 cm)

Width: 9.97 in (25.3 cm)

Length: 17.34 in (44.0 cm)

V400-24p-10GE2 Height: 1.70 in (4.32 cm)

Width: 9.97 in (25.3 cm)

Length: 17.34 in (44.0 cm)

V400-48t-10GE4 Height: 1.70 in (4.32 cm)

Width: 9.97 in (25.3 cm)

Length: 17.34 in (44.0 cm)

V400-48p-10GE4 Height: 1.70 in (4.32 cm)

Width: 15.25 in (38.7 cm)

Length: 17.34 in (44.0 cm)

Click to expand in new window

V400 Unpackaged Weight

V400-24t-10GE2 6.62 lb (3.00 kg)
V400-24p-10GE2 9.08 lb (4.12 kg)
V400-48t-10GE4 7.14 lb (3.26 kg)
V400-48p-10GE4 14.06 lb (6.38 kg)
Click to expand in new window

V400 Packaged Dimensions

V400-24t-10GE2 Height: 4.49 in (11.4 cm)

Width: 14.66 in (37.2 cm)

Length: 22.02 in (55.9 cm)

V400-24p-10GE2 Height: 4.49 in (11.4 cm)

Width: 14.66 in (37.2 cm)

Length: 22.02 in (55.9 cm)

V400-48t-10GE4 Height: 4.49 in (11.4 cm)

Width: 14.66 in (37.2 cm)

Length: 22.02 in (55.9 cm)

V400-48p-10GE4 Height: 4.49 in (11.4 cm)

Width: 19.86 in (50.4 cm)

Length: 22.02 in (55.9 cm)

Click to expand in new window

V400 Packaged Weight

V400-24t-10GE2 9.00 lb (4.08 kg)
V400-24p-10GE2 11.44 lb (5.19 kg)
V400-48t-10GE4 9.69 lb (4.39 kg)
V400-48p-10GE4 16.56 lb (7.50 kg)

Power Specifications

Note

Note

When you use a redundant power supply (RPS), only redundant power – not additive power – is supported. Thus, the PoE ports load does not increase when an RPS is added.
Click to expand in new window

V400 Power Options

V400-24t-10GE2 AC Input: 100-240 VAC, 50/60 Hz, 0.6 A max
V400-24p-10GE2 AC Input: 100-240 VAC, 50/60 Hz, 2.2 A max
DC RPS input: 54 VDC, 18.52 A max
  • PoE ports load to 382 W for AC input only.
  • PoE ports load to 720 W for DC input only.
  • PoE ports load to 720 W for AC+DC input.
V400-48t-10GE4 AC Input: 100-240 VAC, 50/60 Hz, 1.0 A max
V400-48p-10GE4 AC Input: 100-240 VAC, 50/60 Hz, 12.0 - 6.0 A max
DC RPS input: 54 VDC, 18.52 A max
  • PoE ports load to 740 W for AC input only.
  • PoE ports load to 900 W for DC input only.
  • PoE ports load to 1440 W for AC+DC input.
Click to expand in new window

Power Specifications

Minimum1 Heat Dissipation (BTU/hr) Minimum1 Power Consumption (Watts) Maximum1 Heat Dissipation (BTU/hr) Maximum1 Power Consumption (Watts)
V400-24t-10GE2 36.1 10.6 75.2 22.1
V400-24p-10GE2 109.8 32.2 336.8 478.7
V400-48t-10GE4 66.0 19.3 134.8 39.5
V400-48p-10GE4 168.9 49.5 583.2 910.9
VX-RPS-1000 141.3 41.4 3152.8 924

Fan and Acoustic Sound

Click to expand in new window

Fan and Acoustic Sound

  Bystander Sound Pressure2 in dB(A) Declared Sound Power (LWAd)2 in bels
V400-24t-10GE2 41.6 (Duty 30%) /

59.4 (max.)

4.4 (Duty 30%) /

6.2 (max.)

V400-24p-10GE2 47.5 (Duty 30%) /

64.0 (max.)

5.0 (Duty 30%) /

6.7 (max.)

V400-48t-10GE4 43.4 (Duty 30%) /

61.1 (max.)

4.6 (Duty 30%) /

6.4 (max.)

V400-48p-10GE4 48.5 (Duty 30%) /

65.5 (max.)

5.1 (Duty 30%) /

6.8 (max.)

Standards and Environmental Data

Click to expand in new window

Safety Standards

North American Safety of ITE

UL 60950-1 2nd Ed., A2:2014, Listed Device (US)

CSA 22.2 #60950-1-07 2nd Ed., 2014-10 Canada)

Complies with FCC 21CFR 1040.10 (US Laser Safety)

CDRH Letter of Approval (US FDA Approval)

European Safety of ITE

EN 60950-1:2006 +A11+A1+A12+A2

EN 60825-1:2007 (Lasers Safety)

IEC 60950-1:2005 2nd+A1:2009+A2:2013

2014/35/EU Low Voltage Directive

International Safety of ITE

CB Report & Certificate per IEC 60950-1:2005 2nd Ed. + National Differences

AS/NZX 60950-1 (Australia /New Zealand)

Click to expand in new window

V400 Environmental Data

Operating conditions Temperature: 0°C to 50°C (32°F to 122°F) for non-PoE models

Temperature: 0°C to 45°C (32°F to 113°F) for PoE models

Storage and transportation temperature: -40°C to 70°C (-40°F to 158°F)

Humidity: 5% to 95% relative humidity, non-condensing

Altitude: 0 to 3,000 meters (9,850 feet)


1 Minimum is defined as idle, with no ports linked. Maximum is defined as fans high, all ports 100% traffic.
2 At 25°C and 50% PoE load where applicable