Installing an RPS-500p in a Rack
To install the RPS-500p power supply in a 19-inch rack, you need the following:
- Two rack-mounting brackets
and mounting screws (rack-mounting kit) shipped with the power supply
- Four customer-supplied screws
to attach the power supply to a standard 19-inch rack
Caution
Observe all ESD precautions when handling
sensitive electronic equipment.
Caution
Before rack-mounting the
device, ensure that the rack can support it without compromising stability. Otherwise,
personal injury and/or equipment damage may result.
To install the RPS-500p in a rack, follow these steps.
-
Attach the rack-mounting brackets to the RPS-500p using the eight M3x6mm
flathead screws shipped with the power supply.
-
With the rack-mounting brackets attached, position the RPS-500p between the
vertical rack rails of the 19-inch rack as shown in Fastening the RPS-500p to the Rack.
Fastening the RPS-500p to the Rack
1 = RPS-500p |
3 = Mounting screws (4) |
2 = Rails of 19-inch rack |
|
-
Fasten the RPS-500p securely to the rack rails using four customer-supplied
rack screws.
-
If you are installing the RPS-500p in a stacked
configuration, repeat this procedure for each power supply.
-
Connect the RPS-500p to its power source.