Removing a 300 W DC Power Supply
To remove an installed Summit 300 W DC power supply, follow these
steps:
- De-energize the DC circuit.
- Disconnect the DC power cables:
- Pull the cover off the terminal block.
- Loosen the screws that secure the cable terminals to
the terminal block.
- Slide the wires out from under the captive
washers.
Warning
Be sure to disconnect all power cables
before you disconnect the chassis ground wire.
- Disconnect the ground wire:
- Remove the screw that secures the ground wire to the
power supply.
- Move the wire away from the power supply.
-
Push the latching tab toward the power supply handle and
pull outward on the handle to disengage the power supply internal connectors.
- Carefully slide the power supply the rest of the way out
of the switch.