Removing an STK-RPS-1005PS Redundant Power Supply
To remove an installed STK-RPS-1005PS that is attached to a
switch, follow these steps.
Caution
Observe all ESD precautions when handling
sensitive electronic equipment.
Note
The switch should not be powered on
during installation or removal of the power supply. This is not a hot-swap
procedure. Follow the steps in the order specified.
- Unplug the AC power cord from the AC power source first
and then from the power supply.
- Disconnect the RPS
cable from the Redundant Power Supply connector at the rear of the power supply.
- Disconnect the RPS cable from the Redundant Power Supply
connector on the switch.
- If the power supply is installed in a rack, remove it
from the rack:
- Holding the power supply securely, remove the
captive screws that secure it to the STK-RPS-1005CH3 shelf.
- Carefully slide the power supply out of the
shelf.
-
If you want to replace the power supply with
another one, follow the instructions in Installing an STK-RPS-1005PS Redundant Power Supply.