RF Domain member devices inspect every byte of each application
header packet allowed to pass through the WiNG managed network.
When an application is recognized and classified by the WiNG
application recognition engine, administrator defined actions
can be applied to that specific application. For information on
categorizing, filtering and logging the application data allowed
to proliferate the WiNG managed network, refer to Application and Application Group.
Note
The WiNG 7.1 release does not support DPI on
AP505 and AP10 model access points. This feature will be
supported in future releases.
To view the application
utilization statistics:
Select the
Statistics menu from the Web UI.
Expand the
System node on the top, left-hand side of
the screen.
The
System node expands to display the RF
Domains created within the managed network.
Select an
RF
Domain from the list.
The RF
Domain statistics menu displays in the right-hand side of
the screen, with the Health tab selected by default.
Select
Application Visibility from the RF Domain
menu.
The
Application Visibility > Application
screen displays.
Refer to the Top Applications graph to
assess the most prolific, and allowed, application data
passing through RF Domain member devices.
Total Bytes
Displays the top ten RF Domain member
utilized applications in respect to total data
bytes passing through the RF Domain member WiNG
managed network. These are only the
administrator allowed applications approved for
proliferation within the RF Domain member
device.
Bytes Uploaded
Displays the top ten RF Domain member
applications in respect to total data bytes
uploaded through the RF Domain member WiNG
managed network. If this application data is not
aligned with application utilization
expectations, consider allowing or denying
additional applications and categories or
adjusting their precedence (priority).
Bytes Downloaded
Displays the top ten RF Domain member
applications in respect to total data bytes
downloaded from the RF Domain member WiNG
managed network. If this application data is not
aligned with application utilization
expectations, consider allowing or denying
additional applications and categories or
adjusting their precedence (priority).
Refer to the Application Detailed Stats table to assess
specific application data utilization:
Application Name
Lists the RF Domain member allowed
application name whose data (bytes) are passing
through the WiNG managed network.
Uploaded
Displays the number of uploaded application
data (in bytes) passing the through the WiNG
managed network.
Downloaded
Displays the number of downloaded
application data (in bytes) passing the through
the WiNG managed network.
Num Flows
Lists the total number of application data
flows passing through RF Domain member devices
for each listed application. An application flow
can consist of packets in a specific connection
or media stream. Application packets with the
same source address/port and destination
address/port are considered one flow.
Click Clear Application Stats to clear the application
assessment data counters and begin a new assessment.
Periodically, click Refresh to update the statistics
counters to their latest values.
Select the Category tab.
Categories are existing WiNG or
user defined application groups (video, streaming, mobile, audio etc.) that
assist administrators in filtering (allowing or denying) application data. For
information on categorizing application data, refer to Application and Application Group.
The Application Visibility >
Category screen displays.
Refer to the Top
Categories graph to assess the most prolific, and allowed,
application data categories utilized by RF Domain member
devices.
Total Bytes
Displays the top ten RF Domain member application
categories in respect to total data bytes passing through the RF
Domain member WiNG managed network. These are only the
administrator allowed application categories approved for
proliferation within the RF Domain.
Bytes Uploaded
Displays the top ten RF Domain member application
categories in respect to total data bytes uploaded through the
RF Domain member WiNG managed network. If this category data is
not aligned with application utilization expectations, consider
allowing or denying additional categories or adjusting their
precedence (priority).
Bytes Downloaded
Displays the top ten RF Domain member application
categories in respect to total data bytes downloaded from the RF
Domain member WiNG managed network. If this category data is not
aligned with application utilization expectations, consider
allowing or denying additional categories and categories or
adjusting their precedence (priority).
Refer to the Category Detailed
Stats table to assess specific application category data
utilization:
Category Name
Lists the RF Domain member allowed category whose
application data (in bytes) is passing through the WiNG managed
network.
Uploaded
Displays the number of uploaded application category data
(in bytes) passing the through the WiNG managed
network.
Downloaded
Displays the number of downloaded application category data
(in bytes) passing the through the WiNG managed network.
Num Flows
Lists the total number of
application category data flows passing through RF Domain member
devices. A category flow can consist of packets in a specific
connection or media stream. Packets with the same source
address/port and destination address/port are considered one
flow.
Click Clear Category Stats to clear the application
category assessment data counters and begin a new assessment.
Periodically, click Refresh to update the statistics
counters to their latest values.