Use the following commands to configure a CFM segment.
Some of these commands are optional and, if not configured, the default values are used. The following table lists the default values for delay measurement for a CFM segment.

Default Values for Delay Measurement for a CFM Segment
| Configuration | Default Values | 
|---|---|
| Transmit interval | 10 seconds | 
| Window | 60 frames | 
| Timeout | 50 milliseconds | 
| Alarm threshold | 10% | 
| Clear threshold | 95% | 
| Dot1p priority | 6 | 

Default Values for Loss Measurement for a CFM Segment
| Configuration | Default Values | 
|---|---|
| LMM Transmit interval | 90 seconds | 
| Dot1p priority | 6 | 
| Window | 1200 frames | 
| SES threshold | 0.01 | 
| Consecutive available count | 4 | 

Note
The statistics for a particular transmission are preserved until the user triggers the transmission once again or if clear counters cfm segment is triggered from the CLI.