In a SummitStack:
start process name {slot slot}name: Specifies the name of the process.
slot: For a modular chassis, specifies the slot number of the MSM/MM. A specifies the MSM/MM installed in slot A. B specifies the MSM/MM installed in slot B. On a SummitStack, specifies the slot number of the target node. The number is a value from 1 to 8. (This parameter is available only on modular switches and SummitStack.)
You are unable to start a process that is already running.If you try to start a currently running process, for example telnetd, an error message similar to the following appears:
Error: Process telnetd already exists!Note
After you stop a process, do not change the configuration on the switch until you start the process again. A new process loads the configuration that was saved prior to stopping the process. Changes made between a process termination and a process start are lost. Else, error messages can result when you start the new process.As described in the section, Stopping a Process, you can use a single command, rather than multiple commands, to stop and restart a running process.
In a SummitStack:
restart process [class cname | name {slot slot}]