The E4G-200 and E4G-400 have clock sources beyond SyncE. The clock that drives all of the ports on a switch may be selected from:
  • SyncE
  • PTP: An optional 1588v2 module
  • TDM: An optional module which has multiple T1/E1 interfaces for TDM/Ethernet interworking
  • BITS: Building Integrated Timing Supply. A connector capable of receiving a timing signal provided by other building equipment