On a modular switch, the output includes the current temperature and operating status of the I/O modules, management modules, and power controllers.
On a SummitStack, the output includes the current temperature and operating status of all active nodes and their option cards (if any).
The following output shows a sample display of the current temperature and operating status of the installed modules and power controllers:
BD-8810.7 # show temperature Field Replaceable Units Temp (C) Status Min Normal Max -------------------------------------------------------------------------- Slot-1 : 8900-10G24X-c 37.00 Normal -10 0-55 65 Slot-2 : 10G8Xc 33.00 Normal -10 0-50 60 Slot-3 : Slot-4 : Slot-5 : G8Xc 31.50 Normal -10 0-50 60 Slot-6 : Slot-7 : Slot-8 : 10G4Xa 26.00 Normal -10 0-50 60 Slot-9 : Slot-10 : 8900-G96T-c 38.50 Normal -10 0-55 65 MSM-A : 8900-MSM128 31.00 Normal -10 0-55 65 MSM-B : 8900-MSM128 31.00 Normal -10 0-55 65 PSUCTRL-1 : 34.04 Normal -10 0-50 60 PSUCTRL-2 : 35.79 Normal -10 0-50 60
The switch monitors the temperature of each component and generates a warning if the temperature exceeds the normal operating range. If the temperature exceeds the minimum/maximum limits, the switch shuts down the overheated module.
The following output shows a sample display from a SummitStack.
Slot-3 Stack.1 # show temperature Field Replaceable Units Temp (C) Status Min Normal Max -------------------------------------------------------------------------- Slot-1 : Slot-2 : SummitX 34.50 Normal -10 0-54 59 Slot-3 : SummitX 36.50 Normal -10 0-66 67 Slot-4 : Slot-5 : Slot-6 : Slot-7 : Slot-8 : Slot-3 Stack.2 #