This MIB defines the following Extreme-specific SNMPv1 traps generated by Extreme Networks devices.
| Trap | Comments | 
|---|---|
| extremeOverheat | The on-board temperature sensor has reported an overheat condition. The system shuts down until the unit has sufficiently cooled such that operation can begin again. A cold start trap is issued when the unit has come back on line. | 
| extremeFanfailed | One or more of the cooling fans inside the device has failed. A fanOK trap will be sent once the fan has attained normal operation. | 
| extremeFanOK | A fan has transitioned out of a failure state and is now operating correctly. | 
| extremeInvalidLoginAttempt | A user attempted to log into the console or by telnet but was refused access due to an incorrect username or password. | 
| extremePowerSupplyGood | One or more previously bad sources of power to this agent has come back to life without causing an agent restart. | 
| extremePowerSupplyFail | One or more sources of power to this agent has failed. Presumably a redundant power-supply has taken over. | 
| extremeEdpNeighborAdded | This node discovers a new neighbor through Extreme Discovery Protocol (EDP). | 
| extremeEdpNeighborRemoved | No EDP updates are received from this neighbor within the configured timeout period and this neighbor entry is aged out by the device. | 
| extremeModuleStateChanged | Signifies that the value of the extremeSlotModuleState for the specified extremeSlotNumber has changed. Traps are reported only for significant states. | 