Configuring Software Recovery
The default setting and behavior is all. Extreme
Networks strongly recommends using the default setting.
You can configure the system to either take no action or
to automatically reboot the switch after a software task exception using the following
command:
configure
sys-recovery-level [all | none]
Where the following is true:
- all—Configures ExtremeXOS to log an error to
the syslog and automatically reboot the system after any software task exception.
On
modular switches, this command sets the recovery level only for
the MSMs/MMs. The MSM/MM should reboot only if there is a software
exception that occurs on the MSM/MM. The MSM/MM should not reboot
if a software exception occurs on an I/O module.
- none—Configures the system to take no action
if a software task exception occurs. The system does not reboot, which can cause
unexpected switch behavior. On a SummitStack, the sys-recovery-level setting applies
to all active nodes.