BFD over MCT and VxLAN

Bidirectional Forwarding Detection over MCT and VxLAN is supported only for SLX 9740, SLX 9250, SLX 9150, Extreme 8820, Extreme 8720, and Extreme 8520.

Note

Note

BFD over MCT and VxLAN are software based on Extreme 8720, Extreme 8520, SLX 9250, and SLX 9150. For SLX 9740/Extreme 8820, all types of BFD Sessions are hardware based.
Click to expand in new window
BFD over MCT and VxLAN topology
Data flows between client 1 and MCT 1, client 2 and MCT 1, client 1 and MCT2, client 2 and MCT2, and, over ICL or VxLAN, between MCT1 and MCT 2
BFD sessions that are configured on a CCEP interface on an MCT node are software-based in SLX 9150, SLX 9250, Extreme 8520, and Extreme 8720.
Note

Note

BFD sessions that are configured on a CEP interface on an MCT node are hardware-based. Use the BFD engine to transmit the sessions.