Renames a previously configured VLAN.
vlan_name | Specifies the current (old) VLAN name. |
vlan_id | Specifies the VLAN ID. |
name | Specifies a new name for the VLAN. |
N/A.
You cannot change the name of the default VLAN “Default.”
For information on VLAN name requirements and a list of reserved keywords, see Object Names in the ExtremeXOS 30.7 User Guide .
Note
If you use the same name across categories (for example, STPD and EAPS names), we recommend that you specify the identifying keyword as well as the actual name. If you do not use the keyword, the system may return an error message.The following example renames VLAN vlan1 to engineering:
configure vlan vlan1 name engineering
This command was first available in ExtremeXOS 10.1.
The vlan_id variable is first available in ExtremeXOS 16.1.
This command is available on the ExtremeSwitching X435, X440-G2, X450-G2, X460-G2, X465, X590, X620, X670-G2, X690, X695, and X870 series switches.