Testing the WTR timer

Use the fast-wtr-time command to change the timer‘s unit of measure from minutes to seconds, allowing you to test your configuration sooner. Instead of having to wait 5 minutes for the timer to expire, you wait 5 seconds.

The following example configures a WTR time value to seconds.

device# configure terminal
device(config)# erp 1
device(config-erp-1)# fast-wtr-time

Use the no fast-wtr-time command to return the unit of measure to minutes.