To revert an AP5XX, adopted to a WiNG VC or WiNG Controller, to factory-default mode of operation (that is, mode not specified) issue the following command on the WiNG VC/Controller:
#factory-reset deep <AP-HOSTNAME>
Note
The <AP-HOSTNAME> parameter represents the host name of the AP on which the command is to be implemented.The AP's adoption status is lost, it reboots immediately with its mode of operation not specified.
#operational-mode centralized #reload
Or
username | resetDeep (with 'D' in upper case) |
password | FactoryDefaultDeep (with 'F', 'D' and 'D' in upper case) |
Note
The AP reboots in the temporary 'Centralized' mode.