show threshold monitor sfp

Displays details about SFP monitoring limits and their actual values.

Syntax

show threshold monitor sfp all area [ current | rxp | temperature | txp | voltage ]

Parameters

current

Displays the status of the current supplied to the SFP transceiver.

rxp

Displays the status of the incoming laser power in microWatts (µW).

temperature

Displays the temperature in degree Celsius.

txp

Displays the status of the outgoing laser power in microWatts (µW).

voltage

Displays the voltage supplied to the SFP in microVolts (µV).

Modes

Privilege Execution Mode

Usage Guidelines

None

Examples

The following example displays the output of the show threshold-monitor sfp all area current command.

SLX#show threshold monitor sfp all area current
				
Interface       Type            Area            Value           Status        Monitoring Status
------------------------------------------------------------------------------------------------
Eth 0/20        40GSR           Current         7 mAmps         In Range      Monitoring
Eth 0/5         40GSR           Current         6 mAmps         In Range      Monitoring
Eth 0/18        40GSR           Current         6 mAmps         In Range      Monitoring
Eth 0/9         100GSR          Current         7 mAmps         In Range      Monitoring

				

The following example displays the output of the show threshold-monitor sfp all area rxp command.

SLX# show threshold monitor sfp all area rxp

Interface       Type            Area            Value           Status        Monitoring Status
------------------------------------------------------------------------------------------------
Eth 0/20        40GSR           Rxp             708 uWatts      In Range      Monitoring
Eth 0/5         40GSR           Rxp             599 uWatts      In Range      Monitoring
Eth 0/18        40GSR           Rxp             833 uWatts      In Range      Monitoring
Eth 0/9         100GSR          Rxp             700 uWatts      In Range      Monitoring

				

The following example displays the output of the show threshold-monitor sfp all area temperature command.

SLX# show threshold monitor sfp all area temperature

Interface       Type            Area            Value           Status        Monitoring Status
------------------------------------------------------------------------------------------------
Eth 0/28        40GSRINT        Temperature     25 Centigrade   In Range      Monitoring
Eth 0/30        40GSR           Temperature     24 Centigrade   In Range      Monitoring
Eth 0/31        40GSR           Temperature     24 Centigrade   In Range      Monitoring
Eth 0/1         40GSRINT        Temperature     22 Centigrade   In Range      Monitoring
Eth 0/20        40GSR           Temperature     27 Centigrade   In Range      Monitoring
Eth 0/5         40GSR           Temperature     23 Centigrade   In Range      Monitoring
Eth 0/18        40GSR           Temperature     27 Centigrade   In Range      Monitoring
Eth 0/21        40GSR           Temperature     24 Centigrade   In Range      Monitoring
Eth 0/9         100GSR          Temperature     26 Centigrade   In Range      Monitoring
			
			

The following example displays the output of the show threshold-monitor sfp all area txp command.

SLX# show threshold monitor sfp all area txp

Interface       Type            Area            Value           Status        Monitoring Status
------------------------------------------------------------------------------------------------
Eth 0/9         100GSR          Txp             1180 uWatts     In Range      Monitoring

			

The following example displays the output of the show threshold-monitor sfp all area voltage command.

SLX# show threshold monitor sfp all area voltage

Interface       Type            Area            Value           Status        Monitoring Status
------------------------------------------------------------------------------------------------
Eth 0/28        40GSRINT        Voltage         3296 mVolts     In Range      Monitoring
Eth 0/30        40GSR           Voltage         3278 mVolts     In Range      Monitoring
Eth 0/31        40GSR           Voltage         3283 mVolts     In Range      Monitoring
Eth 0/1         40GSRINT        Voltage         3279 mVolts     In Range      Monitoring
Eth 0/20        40GSR           Voltage         3274 mVolts     In Range      Monitoring
Eth 0/5         40GSR           Voltage         3274 mVolts     In Range      Monitoring
Eth 0/18        40GSR           Voltage         3270 mVolts     In Range      Monitoring
Eth 0/21        40GSR           Voltage         3286 mVolts     In Range      Monitoring
Eth 0/9         100GSR          Voltage         3240 mVolts     In Range      Monitoring

			

Related Commands