threshold-timer (management-heartbeat)

Configures the threshold value for listening to heartbeat message from EFA. Used within the management-heartbeat context.

Syntax

threshold-timer time
no threshold-timer

Command Default

By default, threshold value is set at five (5) minutes.

Parameters

time
The time duration in minutes for which this device will listen for a heartbeat message from EFA. Once this time exceeds, the device proceeds to perform the action configured through the action command. A value in the range of 1-30 minutes can be configured.

Modes

Management Heartbeat mode

Examples

The following example sets the threshold value to 30 minutes. This is the maximum value that can be configure for this parameter.

SLX(config-management-heartbeat-manage) # threshold-timer 30