Configures the threshold value for listening to heartbeat message from EFA. Used within the management-heartbeat context.
By default, threshold value is set at five (5) minutes.
action
command. A value in the range of 1-30 minutes can be configured.
Management Heartbeat mode
The following example sets the threshold value to 30 minutes. This is the maximum value that can be configure for this parameter.
SLX(config-management-heartbeat-manage) # threshold-timer 30